<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Portfolio Archive - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/en/portfolio_item/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/portfolio_item/</link>
	<description>Sustainable solutions for life cycle management (LCM) of electrical transformers with insulating oils</description>
	<lastBuildDate>Wed, 10 Dec 2025 16:19:28 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Middle East 2020–2022 – On-load treatment for DBDS and corrosive sulfur (C1) removal</title>
		<link>https://seamarconi.com/en/portfolio_item/middle-east-2020-2022-on-load-treatment-for-dbds-and-corrosive-sulfur-c1-removal/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 10 Dec 2025 14:15:21 +0000</pubDate>
				<category><![CDATA[C1]]></category>
		<category><![CDATA[corrosive sulphur]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=portfolio&#038;p=120869</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/middle-east-2020-2022-on-load-treatment-for-dbds-and-corrosive-sulfur-c1-removal/">&lt;strong&gt;Middle East 2020–2022&lt;/strong&gt; – On-load treatment for DBDS and corrosive sulfur (C1) removal</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2>Scenario</h2>
<p>Transmission utility in the Middle East with a fleet of strategic transformers (380 kV, up to 500 MVA), operating under high load and extreme climatic conditions.<br />
A diagnostic campaign highlighted the widespread presence of DBDS and corrosive sulfur compounds in the insulating oils, with potential risk of metallic sulfide formation and consequent failures.</p>
<h3>Technical characteristics</h3>
<ul>
<li>22 units (transformers, autotransformers, reactors)</li>
<li>Power rating: 60–500 MVA</li>
<li>Voltage: 380 kV</li>
<li>Total oil: approx. 1,710,000 kg; up to 130,000 kg per unit</li>
</ul>
<h2>Problem</h2>
<p>Analyses revealed initial concentrations of <strong>DBDS between 135 and 171 mg/kg</strong> and TCS up to 189 mg/kg.<br />
According to CIGRE guidelines, such values combined with high temperatures and heavy load result in a high risk of corrosion and dielectric degradation.<br />
The utility required an effective long-term solution compatible with service continuity.</p>
<h2><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-120872" src="https://seamarconi.com/wp-content/uploads/2025/12/cigre625table.jpg" alt="" width="1781" height="771" srcset="https://seamarconi.com/wp-content/uploads/2025/12/cigre625table.jpg 1781w, https://seamarconi.com/wp-content/uploads/2025/12/cigre625table-300x130.jpg 300w, https://seamarconi.com/wp-content/uploads/2025/12/cigre625table-1024x443.jpg 1024w, https://seamarconi.com/wp-content/uploads/2025/12/cigre625table-768x332.jpg 768w, https://seamarconi.com/wp-content/uploads/2025/12/cigre625table-1536x665.jpg 1536w" sizes="(max-width: 1781px) 100vw, 1781px" />Solution</h2>
<p>In cooperation with GCC Lab, the utility selected the <strong><a href="https://seamarconi.com/it/servizi/depolarizzazione-da-zolfo-corrosivo-da-dbds-e-non/">Sea Marconi selective depolarization</a></strong>, considered the most effective technique for removing DBDS and sulfur compounds, avoiding the limitations of traditional clay-based treatments.</p>
<p>The intervention was performed <strong>on-load</strong>, using Decontamination Modular Units (DMU) operating 24/7, featuring:</p>
<ul>
<li>closed-loop circulation of the entire oil volume;</li>
<li>chemical–physical treatment using solid reagent and absorbent materials;</li>
<li>integration of filtration, degassing, and dehydration;</li>
<li>dedicated connections to the various compartments (main tank, OLTC, conservator).</li>
</ul>
<p>Outage windows were limited to a few hours for connection/disconnection.</p>
<p><img decoding="async" class="aligncenter size-full wp-image-120871" src="https://seamarconi.com/wp-content/uploads/2025/12/A-scaled-e1765376535639.jpg" alt="" width="789" height="772" srcset="https://seamarconi.com/wp-content/uploads/2025/12/A-scaled-e1765376535639.jpg 789w, https://seamarconi.com/wp-content/uploads/2025/12/A-scaled-e1765376535639-300x294.jpg 300w, https://seamarconi.com/wp-content/uploads/2025/12/A-scaled-e1765376535639-768x751.jpg 768w" sizes="(max-width: 789px) 100vw, 789px" /></p>
<h2>Results</h2>
<p>In the first 12 months, 8 transformers were treated, totalling 809 tonnes of oil.</p>
<p><strong>Results after treatment:</strong></p>
<ul>
<li>DBDS &lt; 5 mg/kg (below detection limit and well below the required &lt; 10 mg/kg)</li>
<li>TCS &lt; 2.5 mg/kg</li>
<li>Chemical–physical properties (water, TAN, DF, IFT, breakdown voltage) fully compliant with IEC 60422 ed. 4; many values comparable to new oils</li>
<li>No significant alarms during treatment</li>
<li>Effectiveness confirmed after 1 year: oils non-corrosive on copper and silver, DBDS stable &lt; 5 mg/kg, parameters within IEC limits</li>
</ul>
<p>The treatment allowed the utility to keep critical units in service, reducing operational risks and improving long-term oil quality.</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/middle-east-2020-2022-on-load-treatment-for-dbds-and-corrosive-sulfur-c1-removal/">&lt;strong&gt;Middle East 2020–2022&lt;/strong&gt; – On-load treatment for DBDS and corrosive sulfur (C1) removal</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Spain 2020/21 Drying of transformer oil and paper</title>
		<link>https://seamarconi.com/en/portfolio_item/spain-202021-drying-of-transformer-oil-and-paper/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 20 Apr 2021 10:18:42 +0000</pubDate>
				<category><![CDATA[water in oil]]></category>
		<category><![CDATA[dehydration]]></category>
		<category><![CDATA[integrated treatment]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=portfolio&#038;p=114415</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/spain-202021-drying-of-transformer-oil-and-paper/">&lt;strong&gt;Spain 2020/21&lt;/strong&gt; Drying of transformer oil and paper</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>3 single-phase transformers installed in a thermoelectric power plant in southern Spain</p>
<p>Technical characteristics of the transformer:</p>
<p>Manufacturer .: xxx<br />
Year: <strong>1977</strong><br />
Power [MVA]: <strong>216</strong><br />
Voltage [KV]: <strong>220/22</strong><br />
Mass of oil [Kg]: <strong>15,650</strong> each.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_right wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="300" height="400" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador1" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1.jpg 300w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1-225x300.jpg 225w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h1 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem</span></h1>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Periodic analyzes of the oil showed a condition of hydration of the cellulosic insulation. The estimated water content in solid insulation is between 3 and 4% by weight, a typical condition for equipment with more than 30 years of service.</p>

		</div>
	</div>
<h1 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h1><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi performed the following activity:</p>
<p><a href="https://seamarconi.com/en/services/dehydration-or-drying-of-transformers-paper-oil/"><strong>Dehydration or drying of transformer (paper/oil)</strong></a></p>
<p>The process was carried out with the transformer on-load under charge.</p>
<p><strong>Detail of the phases of the intervention</strong></p>
<ul>
<li>Hydraulic connection of treatment equipment with temporary out of service transformer</li>
<li>Execution of the dehydration process with the transformer on-load</li>
<li>Disconnection of equipment with transformer on-load</li>
</ul>
<p>&nbsp;</p>
<p><strong>Criteria for stopping treatment</strong></p>
<ul>
<li>Water in oil &lt;10 mg / kg at t&gt; 40 ° C</li>
<li>Breakdown voltage&gt; 70 kV</li>
<li>Extracted water &lt;250 ml / 24h</li>
</ul>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="338" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador2" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2.jpg 600w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2-300x169.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
<div class="boc_spacing " style="height: 40px"></div>
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="338" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador3" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3.jpg 600w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3-300x169.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Treatment details</strong></p>
<p>The process was carried out with the transformer on-load.<br />
The temperature of the oil in the tank (top oil) was kept constantly above 70 ° C through the use of an auxiliary heating equipment.<br />
Simultaneously the oil was recirculated through a vacuum dehydration equipment. Overall, about <strong>15 liters of water</strong> were extracted from each device.</p>
<p><i class="fa fa-clock-o fa-2x "></i><strong>Duration</strong> of the intervention: 6 weeks (2 for each transformer)</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/spain-202021-drying-of-transformer-oil-and-paper/">&lt;strong&gt;Spain 2020/21&lt;/strong&gt; Drying of transformer oil and paper</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>You did not find what you were looking for? Contact us to learn more about your case.</title>
		<link>https://seamarconi.com/en/portfolio_item/non-hai-trovato-quello-che-cercavi-contattaci-per-approfondire-il-tuo-caso/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 20 Dec 2019 15:06:01 +0000</pubDate>
				<guid isPermaLink="false">https://seamarconi.com/it/?post_type=portfolio&#038;p=113223</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/non-hai-trovato-quello-che-cercavi-contattaci-per-approfondire-il-tuo-caso/">You did not find what you were looking for? Contact us to learn more about your case.</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 24px;"><span><strong>Locations</strong> in the world</span></h2><div class="boc_spacing " style="height: 30px"></div><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td><strong>Sea Marconi Technologies s.a.s.</strong><br />
Via Ungheria 20<br />
10093 Collegno (Torino), Italia<br />
Tel : +39 011 234.34.34<br />
Fax: +39 011 234.34.35<br />
eMail: <a href="mailto:info@seamarconi.it">info@seamarconi.it</a><br />
pec: <a href="mailto:seamarconi@pec.it">seamarconi@pec.it</a></td>
<td></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td><strong>Sea Marconi Envirotech Italia S.r.l.</strong><br />
via De Actis contrada Temerano<br />
73050 Seclì (Lecce), Italia<br />
Tel: +39 0836 61.02.70<br />
Fax: +39 0836 61.92.66<br />
eMail: <a href="mailto:info@seamarconi.it">info@seamarconi.it</a><br />
pec: <a href="mailto:seamarconi.envirotech@pec.it">seamarconi.envirotech@pec.it</a></td>
<td></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td><strong>Sea Marconi Energia y Medio Ambiente s.l.</strong><br />
Poligono Ind. El Campillo<br />
Edificio Meatza Planta Baja nº 8<br />
48500 Gallarta (Abanto Zierbena), Spagna<br />
Tel : +34 944 042 449<br />
Fax: +34 944 042 450<br />
eMail: <a href="mailto:info@seamarconi.es">info@seamarconi.es</a></td>
<td></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td><strong>Sea Marconi France S.a.r.l.</strong><br />
12 Rue Maurice KRIEGEL-VALRIMONT<br />
54310 Homécourt, Francia<br />
Tel : +33 03 82.47.57.64<br />
Fax: +33 03 82.47.57.66<br />
eMail: <a href="mailto:info@seamarconi.fr">info@seamarconi.fr</a></td>
<td></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table>
<tbody>
<tr>
<td><strong>Sea Marconi LatinoAmericana S.a.</strong><br />
San Luis 145 &#8211; Piso 2 &#8211; Oficina D<br />
5000 – Córdoba – Argentina<br />
Tel.: +54 351 5893213<br />
eMail: <a href="mailto:info@seamarconi.com.ar">info@seamarconi.com.ar</a></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div></div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 24px;"><span>Contact Us</span></h2>[contact-form-7]</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/non-hai-trovato-quello-che-cercavi-contattaci-per-approfondire-il-tuo-caso/">You did not find what you were looking for? Contact us to learn more about your case.</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Filling a transformer under vacuum and subsequent oil treatment Belgium 2014</title>
		<link>https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-belgium-2014/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Mon, 23 Nov 2015 15:31:14 +0000</pubDate>
				<category><![CDATA[filling]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=103081&#038;lang=it</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-belgium-2014/">Filling a transformer under vacuum and subsequent oil treatment &lt;strong&gt;Belgium 2014&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Situation</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>A global leader in the energy sector</p>
<p>Technical specifications of transformer:</p>
<p>Manufacturer: xxx<br />
Year: <strong>2013 (new)</strong><br />
Power [MVA]: <strong>185</strong><br />
Voltage [kV]: <strong>380/150</strong><br />
Oil mass [kg]: <strong>50.940</strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Transformer empty following transport to destination site.</p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-103081-3167119567]" href="https://seamarconi.com/wp-content/uploads/2015/11/estratto-esiti-analitici-dopo-riempimento-belgio-20141.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="984" height="842" src="https://seamarconi.com/wp-content/uploads/2015/11/estratto-esiti-analitici-dopo-riempimento-belgio-20141.jpg" class="vc_single_image-img attachment-full" alt="" title="estratto-esiti-analitici-dopo-riempimento-belgio-20141" srcset="https://seamarconi.com/wp-content/uploads/2015/11/estratto-esiti-analitici-dopo-riempimento-belgio-20141.jpg 984w, https://seamarconi.com/wp-content/uploads/2015/11/estratto-esiti-analitici-dopo-riempimento-belgio-20141-300x257.jpg 300w, https://seamarconi.com/wp-content/uploads/2015/11/estratto-esiti-analitici-dopo-riempimento-belgio-20141-768x657.jpg 768w" sizes="auto, (max-width: 984px) 100vw, 984px" /></a><figcaption class="vc_figure-caption">Estratto del rapporto di prova con esiti analitici dell’olio a fine intervento</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi implemented the following measures: <a href="http://www.bioenpro.com/wordpress01/soluzioni-medicine/riempimento-olio-trasformatore/"><strong>Filling the transformer under vacuum and oil treatment</strong></a></p>
<p>Details of stages in the procedure</p>
<ul>
<li>connecting and preparing the transformer for vacuum (1 day)</li>
<li>applying the vacuum to the transformer (3 days)</li>
<li>filling under vacuum (2 days)</li>
<li>checking the conservator and purging</li>
<li>treating the oil by circulating it through the Sea Marconi decontamination unit (two and a half days)</li>
<li>sampling the oil for testing at the end of process</li>
<li>disconnecting and uninstalling the site</li>
</ul>
<p>Total <strong>duration</strong> of the process: <strong>8 days</strong></p>

		</div>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element bq_yellow" >
		<div class="wpb_wrapper">
			<blockquote><p>
This treatment was carried out by Sea Marconi in conjunction with the manufacturer of the transformer who installed the transformer at the destination site and assembled the accessories.
</p></blockquote>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-belgium-2014/">Filling a transformer under vacuum and subsequent oil treatment &lt;strong&gt;Belgium 2014&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Filling a transformer under vacuum and subsequent oil treatment France 2013</title>
		<link>https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-france-2013/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 29 Jul 2015 09:27:38 +0000</pubDate>
				<category><![CDATA[filling]]></category>
		<category><![CDATA[oil treatment]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=39602</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-france-2013/">Filling a transformer under vacuum and subsequent oil treatment &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Situation</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Twin transformers installed in a quarry:</p>
<p>Manufacturer: xxx<br />
Year: <strong>1980</strong><br />
Power [MVA]: <strong>250</strong><br />
Voltage [kV]: <strong>400</strong><br />
Oil mass [kg]: <strong>41,000</strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Following a problem associated with <strong>excessive gas formation</strong> diagnosed by another supplier, the latter asked Sea Marconi to drain the oil, keep the transformers under vacuum for a specified period, then refill them with oil and carry out oil treatment.</p>
<p>The procedure presented <strong>severe logistical constraints</strong> as the transformers were located in a quarry. Sea Marconi was able to exploit the <strong>modest size</strong> and <strong>modularity</strong> of its decontamination units for the oil treatment.</p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Sea Marconi solution</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi implemented the following measures:<strong>Draining</strong> the oil from the transformer, <strong>refilling</strong> the transformer under vacuum and oil <strong>treatment</strong></p>

		</div>
	</div>
<div class="acc_holder  rounded  "><div class="acc_item"><h4 class="accordion"><span class="acc_control "></span><span class="acc_heading">Details of stages in the process</span></h4><div class="accordion_content"></p>
<ul>
<li>Installation of the site and piping connections</li>
<li>draining and preparation of the transformer for vacuum</li>
<li>applying the vacuum to the transformer</li>
<li>keeping the transformer under vacuum</li>
<li>refilling under vacuum</li>
<li>checking the conservator and purging</li>
<li>treating the oil by circulating it through Sea Marconi decontamination units</li>
<li>sampling the oil for testing at the end of the process</li>
<li>disconnection and uninstalling the site</li>
</ul>
<p></div></div><div class="acc_item"><h4 class="accordion"><span class="acc_control "></span><span class="acc_heading">Criteria for terminating the treatment</span></h4><div class="accordion_content">The treatment was terminated when the following oil parameters were achieved (as agreed with the client)</p>
<ul>
<li>water in the oil &lt; 5mg/kg at 20°C (sampling by aspiration in the treatment unit);</li>
<li>oil dielectric strength &gt; 60 kV;</li>
<li>amount of water extracted &lt; 0.25 litre/24 hours;</li>
<li>temperature 70°C during the final treatment.</li>
</ul>
<p></div></div><div class="acc_item"><h4 class="accordion"><span class="acc_control "></span><span class="acc_heading">Details of treatment</span></h4><div class="accordion_content"></p>
<ul>
<li>Vacuum achieved:&lt; 5 mBAR</li>
<li>Oil circulation flow rate:4000 l/h (T1), 4500 l/h (T2)</li>
<li>Average oil temperature at the top of the tank:74.3°C (T1), 74.4°C (T2)</li>
<li>Average oil temperature at the bottom of the tank:53°C (T1), 55°C (T2)</li>
<li>Extracted water:3.1 litres (T1), 2.5 litres (T2)</li>
<li>Dielectric strength:75.1 kV</li>
<li>Water content in oil:6mg/kg (T1), 7mg/kg (T2)</li>
</ul>
<p></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><i class="fa fa-clock-o fa-2x "></i><strong> Duration</strong> of treatment: <strong>3</strong> days (T1) and <strong>4</strong> days (T2)</p>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_42bc3b3cd5382488c9649efd61edc760"><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/07/caso-riempimento-francia2013_2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/07/caso-riempimento-francia2013_2-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/07/caso-riempimento-francia2013_1.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/07/caso-riempimento-francia2013_1-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/07/grafico_vuoto_tr2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/07/grafico_vuoto_tr2-600x376.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/07/acqua-estratta-riempiemento.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/07/acqua-estratta-riempiemento-600x365.jpg" alt="" />
								
							</a>	</div></div></div></div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-a-transformer-under-vacuum-and-subsequent-oil-treatment-france-2013/">Filling a transformer under vacuum and subsequent oil treatment &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Filling and dehydrating transformer oil France 2012 water in papers</title>
		<link>https://seamarconi.com/en/portfolio_item/filling-and-dehydrating-transformer-oil-france-2012-water-in-papers/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 12 Jun 2015 14:55:26 +0000</pubDate>
				<category><![CDATA[filling]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=17220</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-and-dehydrating-transformer-oil-france-2012-water-in-papers/">Filling and dehydrating transformer oil &lt;strong&gt;France 2012&lt;/strong&gt; water in papers</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Situation</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>A global leader in the energy and infrastructure sector</p>
<p>Technical specifications of transformer:</p>
<p>Manufacturer: xxx<br />
Year: <strong>2012 (new)</strong><br />
Power [MVA]: <strong>80</strong><br />
Voltage [kV]: <strong>227/21/21</strong><br />
Oil mass [kg]: <strong>26.700</strong></p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="400" src="https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers.jpg" class="vc_single_image-img attachment-full" alt="" title="riempimento_villers" srcset="https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers.jpg 600w, https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers-300x200.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Following an initial request to <strong>fill</strong> the new transformer, when the Sea Marconi technicians arrived they noticed there was free <strong>water inside</strong> the transformer.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element bq_yellow" >
		<div class="wpb_wrapper">
			<blockquote><p>
This was due to the transformer not being properly sealed prior to transportation.
</p></blockquote>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_8bf300d142a1c2f612b5f5cd81f7f38e"><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione2-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione1.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione1-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/06/acqua-libera_villers3.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/06/acqua-libera_villers3-600x380.jpg" alt="" />
								
							</a>	</div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi carried out a rather complex operation in three separate stages:</p>
<ol>
<li><strong><a href="https://seamarconi.com/servizi/disidratazione-o-deumidificazione-trasformatore-carte/">Dehydration of the papers</a> by the direct &#8220;hot oil + vacuum&#8221; drying technique</strong><br />
This phase involves applying a vacuum to the transformer tank, filling it with hot oil to cover the windings, draining the transformer rapidly and repeating the process until the established values are achieved (water &lt; 10mg/kg; dielectric strength &gt; 70kV; amount of water extracted &lt; 0.25 litre/24 hours).</li>
<li><strong>Refilling and treatment</strong><br />
This phase involves applying a vacuum to the transformer tank, filling it with oil and subsequent physical treatment of the vents</li>
</ol>
<p>The process took just over <strong>two weeks</strong>, during which <strong>2.85 litres of water</strong> was extracted from the oil/transformer system.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="208" src="https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta.jpg" class="vc_single_image-img attachment-full" alt="" title="acqua-estratta" srcset="https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta.jpg 600w, https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta-300x104.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/filling-and-dehydrating-transformer-oil-france-2012-water-in-papers/">Filling and dehydrating transformer oil &lt;strong&gt;France 2012&lt;/strong&gt; water in papers</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Oil treatment in extreme logistical conditions Italy 2015</title>
		<link>https://seamarconi.com/en/portfolio_item/oil-treatment-in-extreme-logistical-conditions-italy-2015/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 27 May 2015 10:05:40 +0000</pubDate>
				<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=15075</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/oil-treatment-in-extreme-logistical-conditions-italy-2015/">Oil treatment in extreme logistical conditions &lt;strong&gt;Italy 2015&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Situation</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Hydroelectricity company. The transformer is located <strong>in the Adamello peaks</strong> (Lombardy).</p>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_db5e9de84649ee1b060283f0597be0e6"><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi_bus-e1432723692475.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi_bus-e1432723692475-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi_pista-e1432723671647.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi_pista-e1432723671647-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi1-e1432723707149.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/05/adamello_quattroterzi1-e1432723707149-600x380.jpg" alt="" />
								
							</a>	</div></div></div><div class="boc_spacing " style="height: 20px"></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>There were extreme logistical difficulties associated with reaching the operating site: the access route was a steep slope at high altitude and there was more than a metre of snow. Helicopter was the only possible means of transporting the oil treatment machinery, so there were stringent weight constraints.</p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi overcame the stringent logistical constraints to access the operating site by using a new design of <strong><a href="https://seamarconi.com/impianti/impianti-per-il-trattamento-olio-e-trasformatori/">mobile processing unit (DMU)</a></strong>.These new units are designed and manufactured to be <strong>lightweight</strong> (estimated empty weight is 590kg), and <strong>smaller in size</strong> (L 1,560 x W 1,000 x H 1,440 (mm), so they&#8217;re <strong>easy to handle</strong>. It also means they can be transported by road with no need to unload them from the trailer, so they can be taken to areas with very tight access points (off-shore platforms, quarries, bunkers, underground power stations, etc.)</p>
<p>Because the Sea Marconi decontamination unit is lighter in weight and smaller in size, it was suspended from the <strong>helicopter</strong> with a chain hooked through its anchoring rings for transportation to the power station.</p>

		</div>
	</div>

	<div class="wpb_video_widget wpb_content_element vc_clearfix   vc_video-aspect-ratio-169 vc_video-el-width-100 vc_video-align-left" >
		<div class="wpb_wrapper">
			
			<div class="wpb_video_wrapper"><iframe loading="lazy" title="L&#039;impianto di trattamento olio e trasformatore supera i vincoli logistici estremi" width="413" height="310" src="https://www.youtube.com/embed/kaBHWaIXJGo?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe></div>
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Specifically, there are two devices that perform the following functions: oil is sucked out and pumped back in (<strong>draining and refilling</strong>), oil is <strong>heated</strong> to a preset temperature, solid suspended particles are <strong>filtered</strong> out, and the transformer is <strong>degassed</strong> and <strong>dried</strong> under vacuum.These functions can also be carried out whilst the oil is circulating in a continuous, closed circuit between the unit and the transformer.<br />
The control and safety systems installed mean the system can even be used without intervention by the operator.The unit is designed to operate at the following settings:</p>
<ul>
<li>Nominal flow: 160 ÷ 600 l/h</li>
<li>Maximum heating temperature: 80°C</li>
<li>Oil temperature in the degassing chamber: 60 ÷ 70°C</li>
<li>Heating capacity ?t = 40°C at 600l/h</li>
<li>Max pressure: 6 bar</li>
<li>Absolute pressure in the degassing chamber: &lt; 1 mBAR at full performance</li>
<li>Filtration: 2 microns</li>
</ul>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Structural features</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The unit is mounted on a stainless steel AISI 304 frame and is fitted with wheels, fork guides for lifting with a forklift truck, anchoring rings for lifting by crane, and corner blocks for anchoring to road trailers.<br />
All elements of the hydraulic circuit, including connection points for the flexible suction and delivery pipes, are contained in a sealed tank to contain any of accidental loss of oil.<br />
The hydraulic system, degassing chamber, filtration bodies and heater are made of AISI 304 stainless steel.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="500" height="201" src="https://seamarconi.com/wp-content/uploads/2015/05/dmu12600_particolare2_500px.jpg" class="vc_single_image-img attachment-full" alt="" title="dmu12600_particolare2_500px" srcset="https://seamarconi.com/wp-content/uploads/2015/05/dmu12600_particolare2_500px.jpg 500w, https://seamarconi.com/wp-content/uploads/2015/05/dmu12600_particolare2_500px-300x121.jpg 300w" sizes="auto, (max-width: 500px) 100vw, 500px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"></div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/oil-treatment-in-extreme-logistical-conditions-italy-2015/">Oil treatment in extreme logistical conditions &lt;strong&gt;Italy 2015&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sweden 2012 PCB in oil and transformer</title>
		<link>https://seamarconi.com/en/portfolio_item/sweden-2012-pcb-in-oil-and-transformer/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Thu, 09 Apr 2015 14:03:04 +0000</pubDate>
				<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=13579</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/sweden-2012-pcb-in-oil-and-transformer/">&lt;strong&gt;Sweden 2012&lt;/strong&gt; PCB in oil and transformer</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><b>Primary alluminiun factory: 8 Rectifier Transformers </b>(Sweden)</p>
<p>Nameplate data of transformers:</p>
<p>Manufact: xxx<strong><br />
</strong>Year: <strong>1930<br />
</strong>Power [MVA]: <strong>19<br />
</strong>Voltage [KV]: <strong>13<br />
</strong>Oil Mass [Kg]: <strong>15.000<br />
</strong>Oil type: <strong>mineral blended</strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><a href="https://seamarconi.com/en/services/depolarisation-against-corrosive-sulphur-in-oil/"><strong>Selective depolarization</strong></a> treatment<b> (Chedcos) </b>in order to remove the<b> </b>DBDS + <strong><a href="https://seamarconi.com/en/services/dehalogenation-removal-of-pcbs-in-oil/">dehalogenation treatment</a> (CDP Process)</strong> in orderr to remove the PCBs both from oil and transformers. The treatments were performed on-site, on-line and on-load (transformer in servise and under charge during the treatment).</p>
<p>The treatments were carried out with the following guarantees: <strong>DBDS &lt; 10 mg/kg,</strong> <strong>PCBs &lt; 2 mg/Kg</strong> restoring also the other oil parameters as suggested by IEC 60422 ed. 4, 2013</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="0" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h4>Before the treatments</h4>
</td>
<td style="text-align: center;" valign="top">
<h4>After the treatments</h4>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><b>PCBs </b>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>29</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>0,37</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><b>DBDS </b>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>18</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>&lt; 5</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>IFT </strong>[mN/m]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>24</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>42</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>CCD Test</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;">corrosive</span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;">NOT corrosive</span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;">0,34</span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>0,01</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;">0,230</span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>0,002</b></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="479" height="358" src="https://seamarconi.com/wp-content/uploads/2015/04/caso7_transfo-svezia.jpg" class="vc_single_image-img attachment-full" alt="" title="caso7_transfo-svezia" srcset="https://seamarconi.com/wp-content/uploads/2015/04/caso7_transfo-svezia.jpg 479w, https://seamarconi.com/wp-content/uploads/2015/04/caso7_transfo-svezia-300x224.jpg 300w" sizes="auto, (max-width: 479px) 100vw, 479px" /></div><figcaption class="vc_figure-caption">Dehalogenated and depolarizated transformers</figcaption>
		</figure>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/sweden-2012-pcb-in-oil-and-transformer/">&lt;strong&gt;Sweden 2012&lt;/strong&gt; PCB in oil and transformer</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PCBs and C2 and C4 corrosion, extreme logistics France 2013</title>
		<link>https://seamarconi.com/en/portfolio_item/removal-pcbs-and-c2-and-c4-corrosion-extreme-logistics-france-2013/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Sat, 22 Feb 2014 17:08:48 +0000</pubDate>
				<category><![CDATA[C2]]></category>
		<category><![CDATA[C4]]></category>
		<category><![CDATA[CDP Process]]></category>
		<category><![CDATA[PCB]]></category>
		<category><![CDATA[PCB treatment]]></category>
		<category><![CDATA[corrosive sulphur]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=10009</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/removal-pcbs-and-c2-and-c4-corrosion-extreme-logistics-france-2013/">PCBs and C2 and C4 corrosion, extreme logistics &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Hydro Power Plant</p>
<p>The transformer is located near a river dam with extreme logistical and environmental constraints. The option of changing the oil was discarded immediately because of the enormous difficulties in handling (see. Photo) around the transformer. At the same time the fuller earth techniques would not solve the functional criticalities of the system “oil – transformer”.</p>
<p><strong>Nameplate data of the transformer</strong></p>
<p>Year: 1969<br />
Power [MVA]: 105<br />
Voltage [KV]: 225<br />
Oil Mass [Kg]: 29.000<br />
Oil Type: paraffinic non inhibited</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-10009-3740650433]" href="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione4.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="500" height="281" src="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione4.jpg" class="vc_single_image-img attachment-full" alt="" title="trattamento_olio_PCB_depolarizzazione4" srcset="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione4.jpg 500w, https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione4-300x169.jpg 300w" sizes="auto, (max-width: 500px) 100vw, 500px" /></a>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problem </span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>For this case, Sea Marconi has done a detailed study using multidetection diagnostic tools from which emerged the following critical factors:</p>
<ol>
<li><strong>PCBs</strong> above the threshold due to cross contamination caused by previous treatment performed by unskilled operator in a sensitive environment (water for cultivation)</li>
<li>Corrosion<strong> C2 (NON DBDS &amp; Corrosive sulfur)</strong> with DBDS equivalent = 70 mg/Kg and CCD test result as corrosive without DBDS</li>
<li>corrosion <strong>C4 (NON sulfur corrosion &amp; metal dissolution)</strong>, due to presence of copper in organ metallic form</li>
<li><strong>dielectric properties</strong> of oil non standard</li>
</ol>
<p>there are no electrical faults, there are thermal defects but only a normal aging of the insulation solid</p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Solution </span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi proposed and performed and integrated treatment based on <a title="Depolarization from corrosive sulfur" href="http://www.bioenpro.com/wordpress01/?soluzioni-medicine=depolarizzazione-composti-corrosivi&amp;lang=en"><strong>selective depolarization</strong></a> (Chedcos) and <a title="Dehalogenation of PCBs in oil" href="http://www.bioenpro.com/wordpress01/?soluzioni-medicine=dealogenazione-pcb-in-olio&amp;lang=en"><strong>dehalogenation of PCB</strong></a> in oil (CDP Process). The treatment was performed on-site and on-load (transformer in service and under load) with a total duration of 22 days, of which 16 for the treatment part.</p>
<p>The solution Sea Marconi won and convinced primarily for the modularity of the treatment unit (DMU), with reduced weight and size and therefore extremely easy to handle in an area with extreme logistical constraints.<br />
Not only, the service Sea Marconi was able to heal, with just one treatment, the problems of corrosivity and the problems of PCB contamination, both the poor dielectric oil.</p>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_e50cb5e3b93bb4718ea5967a0adc2356"><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione5.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione5.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione2.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione1.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2014/02/trattamento_olio_PCB_depolarizzazione1.jpg" alt="" />
								
							</a>	</div></div></div><div class="boc_spacing " style="height: 30px"></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top"></td>
<td valign="top">
<h4 style="text-align: center;">Before the treatment</h4>
</td>
<td valign="top">
<h4 style="text-align: center;"><strong><span style="color: #339966;">After the treatment</span></strong></h4>
</td>
</tr>
<tr>
<td valign="top">Acidity TAN [mgKOH/g]</td>
<td valign="top">
<p style="text-align: center;">0,281</p>
</td>
<td valign="top">
<p style="text-align: center;">&lt; 0,01</p>
</td>
</tr>
<tr>
<td valign="top">Interfacial tension [mN/m]</td>
<td valign="top">
<p style="text-align: center;">18,08</p>
</td>
<td valign="top">
<p style="text-align: center;">33,30</p>
</td>
</tr>
<tr>
<td valign="top">Moisture [mg/Kg]</td>
<td valign="top">
<p style="text-align: center;">6</p>
</td>
<td valign="top">
<p style="text-align: center;">2</p>
</td>
</tr>
<tr>
<td valign="top">Dissipation factor 90 °C</td>
<td valign="top">
<p style="text-align: center;">1.023</p>
</td>
<td valign="top">
<p style="text-align: center;">0,09211</p>
</td>
</tr>
<tr>
<td valign="top">Breakdown voltage [KV]</td>
<td valign="top">
<p style="text-align: center;">73,10</p>
</td>
<td valign="top">
<p style="text-align: center;">75</p>
</td>
</tr>
<tr>
<td valign="top">DBDS [mg/Kg]</td>
<td valign="top">
<p style="text-align: center;">&lt; 5</p>
</td>
<td valign="top">
<p style="text-align: center;">&lt; 5</p>
</td>
</tr>
<tr>
<td valign="top">Corrosive sulfur CCD test</td>
<td valign="top">
<p style="text-align: center;">corrosive</p>
</td>
<td valign="top">
<p style="text-align: center;">Non corrosive</p>
</td>
</tr>
<tr>
<td valign="top">Total corrosive sulfur (DBDS equivalent) [mg/Kg]</td>
<td valign="top">
<p style="text-align: center;">69</p>
</td>
<td valign="top">
<p style="text-align: center;">8</p>
</td>
</tr>
<tr>
<td valign="top">Copper [mg/Kg]</td>
<td valign="top">
<p style="text-align: center;">64</p>
</td>
<td valign="top">
<p style="text-align: center;">2</p>
</td>
</tr>
<tr>
<td valign="top">PCBs [mg/Kg]</td>
<td valign="top">
<p style="text-align: center;">71</p>
</td>
<td valign="top">
<p style="text-align: center;">25</p>
</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The brilliant results achieved are the result of a mix of excellence:</p>
<ul>
<li>Innovation and technical treatment plants and transformer oil,</li>
<li>the use of specific reagents patented,</li>
<li>the competence of technicians Sea Marconi,</li>
<li>certification of the analytical test results</li>
</ul>
<p>This case brings together a number of peculiarities that make it <strong>unique worldwide</strong>. It has required a major effort to research, development and innovation. This has generated a series of advanced methodologies focused to multidetection; moreover this case has allowed us to study new treatment methodologies and instrumental configurations for monitoring entirely new.</p>
<p>Since this case is expected to publish some results in trade magazines from IEEE and Analitcal chemistry.</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/portfolio_item/removal-pcbs-and-c2-and-c4-corrosion-extreme-logistics-france-2013/">PCBs and C2 and C4 corrosion, extreme logistics &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Removal of PCBs and environmental protection France 2012</title>
		<link>https://seamarconi.com/en/portfolio_item/removal-of-pcbs-and-environmental-protection-france-2012/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:54:14 +0000</pubDate>
				<category><![CDATA[CDP Process]]></category>
		<category><![CDATA[France]]></category>
		<category><![CDATA[BAT]]></category>
		<category><![CDATA[PCB]]></category>
		<category><![CDATA[PCB free]]></category>
		<category><![CDATA[PCB treatment]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4220</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/portfolio_item/removal-of-pcbs-and-environmental-protection-france-2012/">Removal of PCBs and environmental protection &lt;strong&gt;France 2012&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Nameplate data of transformer:</p>
<p>Trasformatore: grid transformer<br />
Manufact: xxx<br />
Year: <strong>1970</strong><br />
Power [MVA]: <strong>70<br />
</strong>Voltage [KV]:<strong> 225<br />
</strong>Oil mass [Kg]: <strong>38.000</strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution Sea Marconi</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><b>Dealogenazione (CDP Process®)</b> treatment in order to remove the <b>PCBs,</b> performed on-load (this means that the transformer is in service and under load during the treatment)</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="508" height="353" src="https://seamarconi.com/wp-content/uploads/2013/05/caso20_andamento-PCB.jpg" class="vc_single_image-img attachment-full" alt="" title="caso20_andamento-PCB" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso20_andamento-PCB.jpg 508w, https://seamarconi.com/wp-content/uploads/2013/05/caso20_andamento-PCB-300x208.jpg 300w" sizes="auto, (max-width: 508px) 100vw, 508px" /></div><figcaption class="vc_figure-caption">Trend of PCBs and chlorine content during the dehalogenation treatment (CDP Process)</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="500" height="375" src="https://seamarconi.com/wp-content/uploads/2013/05/caso-20-trasformatore-con-pcb.jpg" class="vc_single_image-img attachment-full" alt="" title="caso-20-trasformatore-con-pcb" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso-20-trasformatore-con-pcb.jpg 500w, https://seamarconi.com/wp-content/uploads/2013/05/caso-20-trasformatore-con-pcb-300x225.jpg 300w" sizes="auto, (max-width: 500px) 100vw, 500px" /></div><figcaption class="vc_figure-caption">Transformer on which the dehalogenation was done<p>The post <a href="https://seamarconi.com/en/portfolio_item/removal-of-pcbs-and-environmental-protection-france-2012/">Removal of PCBs and environmental protection &lt;strong&gt;France 2012&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>