<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>DGA Archives - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/en/tag/dga/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/tag/dga/</link>
	<description>Sustainable solutions for life cycle management (LCM) of electrical transformers with insulating oils</description>
	<lastBuildDate>Fri, 20 Mar 2026 11:28:47 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>My Transfo on the Road arrives in Lyon: a new local chapter for technical knowledge sharing</title>
		<link>https://seamarconi.com/en/newsblog/my-transfo-on-the-road-arrives-in-lyon-a-new-local-chapter-for-technical-knowledge-sharing/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Thu, 29 Jan 2026 15:02:26 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[diagnosis]]></category>
		<category><![CDATA[lifecycle management]]></category>
		<category><![CDATA[insulating oil]]></category>
		<category><![CDATA[oil treatment]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=120963</guid>

					<description><![CDATA[<p>&#160; My Transfo on the Road is the local extension of the international My Transfo conference, promoted and organised by Sea Marconi since 2002. After more than twenty years of international dialogue and technical exchange, the My Transfo experience is now moving closer to local markets with a focused, one-day professional format. The first stop of this new initiative will</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/en/newsblog/my-transfo-on-the-road-arrives-in-lyon-a-new-local-chapter-for-technical-knowledge-sharing/">Read more</a></p>
<p>The post <a href="https://seamarconi.com/en/newsblog/my-transfo-on-the-road-arrives-in-lyon-a-new-local-chapter-for-technical-knowledge-sharing/">My Transfo on the Road arrives in Lyon: a new local chapter for technical knowledge sharing</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-120964" src="https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma.png" alt="" width="1201" height="627" srcset="https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma.png 1201w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-300x157.png 300w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-1024x535.png 1024w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-768x401.png 768w" sizes="(max-width: 1201px) 100vw, 1201px" /></p>
<p>&nbsp;</p>
<p>My Transfo on the Road is the local extension of the international <a href="https://www.mytransfo.com/" target="_blank" rel="noopener"><strong>My Transfo</strong></a> conference, promoted and organised by Sea Marconi since 2002. After more than twenty years of international dialogue and technical exchange, the My Transfo experience is now moving closer to local markets with a focused, one-day professional format.</p>
<p>The first stop of this new initiative will take place in <a href="https://www.mytransfo.com/my-transfo-on-the-road/my-transfo-on-the-road-2026-lyon/" target="_blank" rel="noopener"><strong>Lyon on 10 June 2026</strong></a>, with an event entirely delivered in French and dedicated to transformers and insulating fluids.</p>
<p>My Transfo on the Road is designed to bring local markets the solutions, expertise and know-how developed within the international My Transfo conference. The knowledge shaped and shared by leading global experts at My Transfo is transferred and made available to local contexts through the My Transfo on the Road format.</p>
<h3>A focused format, high technical value</h3>
<p>The Lyon edition offers an intensive one-day programme conceived to maximise participants’ time and professional value. Topics under development include sampling of insulating liquids, transformer hydration pathologies, insulating fluid diagnostics, stray water phenomena, rehabilitation of transformer fleets, laboratory data management, and electrical testing best practices.</p>
<p>The event brings together a qualified local network of utilities, engineers, laboratories, manufacturers and technical experts, fostering direct dialogue and concrete exchange on real operational challenges.</p>
<h3>A local event, aligned with the My Transfo vision</h3>
<p>My Transfo on the Road maintains the core principles of the My Transfo platform: knowledge sharing, scientific rigour, independence of content and a strong connection between research and field experience. The local format allows these values to be expressed in the national language, with topics and speakers closely connected to regional contexts.</p>
<p>With Lyon 2026, Sea Marconi launches the first step of a broader roadmap that will extend My Transfo on the Road to other European and international markets. The second stop of the initiative is already scheduled to take place in <strong>Madrid in October 2026</strong>.</p>
<p>The post <a href="https://seamarconi.com/en/newsblog/my-transfo-on-the-road-arrives-in-lyon-a-new-local-chapter-for-technical-knowledge-sharing/">My Transfo on the Road arrives in Lyon: a new local chapter for technical knowledge sharing</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>My Transfo 2023: A Successful Return for oil and Transformer Management</title>
		<link>https://seamarconi.com/en/newsblog/my-transfo-2023-a-successful-return-for-oil-and-transformer-management/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 24 Oct 2023 13:13:33 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[My Transfo]]></category>
		<category><![CDATA[training]]></category>
		<category><![CDATA[oil treatment]]></category>
		<category><![CDATA[corrosive sulphur]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=116678</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/newsblog/my-transfo-2023-a-successful-return-for-oil-and-transformer-management/">My Transfo 2023: A Successful Return for oil and Transformer Management</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>My Transfo 2023, the leading event in Europe for discussing transformer and insulating fluid management, made a triumphant return on October 3rd and 4th. This year&#8217;s event was a resounding success with 160 participants, 23 speakers, and representatives from 22 nationalities.<br />
After a hiatus due to the COVID-19 pandemic in 2018, the 2023 edition impressed everyone with high-quality content and participant satisfaction well beyond expectations.</p>
<p>A heartfelt thank you for their dedication and professionalism goes out to all the speakers, with special recognition to Vander Tumiatti, Franco Salomone, Oleg Roizman, Diego Robalino, Fabio Scatiggio, who graciously provided the following interviews.</p>

		</div>
	</div>
<div class="boc_spacing " style="height: 20px"></div>
	<div class="wpb_video_widget wpb_content_element vc_clearfix   vc_video-aspect-ratio-169 vc_video-el-width-100 vc_video-align-left" >
		<div class="wpb_wrapper">
			
			<div class="wpb_video_wrapper"><iframe title="Interviews collected at My Transfo 2023, 3 and 4 October" width="500" height="281" src="https://www.youtube.com/embed/hzNLEMn1lPw?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe></div>
		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The entire multimedia gallery is available on the event&#8217;s website.</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>In 2001, Sea Marconi reflected on the need for an event where professionals could exchange experiences on emerging challenges in the transformer and insulating fluid industry. From that idea, My Transfo was born. The tenth edition (in addition to three editions in Brazil) took place in Turin on October 3rd and 4th, and since its first edition in 2002, the event has consistently grown to become a European reference point.</p>

		</div>
	</div>
<div class="boc_spacing " style="height: 20px"></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<h2 class="silicon-elementor-highlighted-heading__title h1 text-center pt-1 pt-xl-2 mb-4" style="text-align: center;"><span class="si-multipurpose-text__before">Could you not attend My Transfo?</span></h2>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p style="text-align: center;">You have the opportunity to stay updated with the conference proceedings and all the presentations shown during the event</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_right wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a href="https://www.mytransfo.com/proceedings-of-my-transfo-2023-and-presentations/" target="_blank" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="850" height="478" src="https://seamarconi.com/wp-content/uploads/2023/10/banner_proceedings_final.png" class="vc_single_image-img attachment-full" alt="" title="banner_proceedings_final" srcset="https://seamarconi.com/wp-content/uploads/2023/10/banner_proceedings_final.png 850w, https://seamarconi.com/wp-content/uploads/2023/10/banner_proceedings_final-300x169.png 300w, https://seamarconi.com/wp-content/uploads/2023/10/banner_proceedings_final-768x432.png 768w" sizes="(max-width: 850px) 100vw, 850px" /></a>
		</figure>
	</div>
</div></div></div></div></div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/newsblog/my-transfo-2023-a-successful-return-for-oil-and-transformer-management/">My Transfo 2023: A Successful Return for oil and Transformer Management</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Eurodoble Rome, a great opportunity for professional enrichment</title>
		<link>https://seamarconi.com/en/newsblog/eurodoble-roma/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 26 Oct 2022 08:35:48 +0000</pubDate>
				<category><![CDATA[bioeconomia]]></category>
		<category><![CDATA[DBDS]]></category>
		<category><![CDATA[DGA]]></category>
		<category><![CDATA[diagnosis]]></category>
		<category><![CDATA[transformer]]></category>
		<category><![CDATA[oil treatment]]></category>
		<category><![CDATA[corrosive sulphur]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=115957</guid>

					<description><![CDATA[<p>The EuroDoble is one of the main appointments for the technical updating of the sector in Europe. This year the event was held in Rome from 25 to 28 October 2022 on two main topics: Asset Management and Digital Substations. At the invitation of Doble Sea Marconi had the honor of opening the technical part of the event (keynote speech)</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/en/newsblog/eurodoble-roma/">Read more</a></p>
<p>The post <a href="https://seamarconi.com/en/newsblog/eurodoble-roma/">Eurodoble Rome, a great opportunity for professional enrichment</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The EuroDoble is one of the main appointments for the technical updating of the sector in Europe. This year the event was held in <strong>Rome</strong> from 25 to 28 October 2022 on two main topics: Asset Management and Digital Substations.<br />
At the invitation of Doble Sea Marconi had the honor of opening the technical part of the event (keynote speech) tracing the path on what was then the common denominator of the interventions in the Asset management part, namely sustainability. The speech in question was given by Vander Tumiatti (Sea Marconi General partner) on &#8220;Bio and granular economy as sustainable opportunities towards clean energy&#8221;.</p>
<p>In addition to this intervention, Sea Marconi intervened at the Eurodoble with two other speeches:</p>
<ul>
<li>&#8220;Filling New Power Transformers with Insulating Fluid Prior to the First Energization: Best Practices&#8221; held by Eng. Riccardo Actis (technical service manager), and</li>
<li>&#8220;Additives in Natural Ester: Their Efficacy and Degradation Rate Under Thermal Aging Conditions&#8221; held by Riccardo Maina (laboratory manager).</li>
</ul>
<p>The Eurodoble was also an opportunity for Sea Marconi to show the participants 2 absolute novelties: the <a href="https://seamarconi.com/it/?p=115849"><strong>SmartNosy</strong></a> and the <a href="https://seamarconi.com/it/?p=115242"><strong>DGA Experience</strong></a>.<br />
<strong>SmartNosy is the first system in the world for monitoring the state of health of cast resin transformers</strong>. DGA Experience is a package of services, products, solutions for <strong>laboratories that intend to improve their performance in the analysis of dissolved gases</strong>. I won&#8217;t dwell here on the extraordinary innovations introduced by these two services, I invite you to click on the links just above to learn more.</p>

<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221027101016-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221027101016-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221026092110-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221026092110-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221027100834-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221027100834-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221025170906-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221025170906-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221026143416-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221026143416-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221025170217-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221025170217-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221027101207-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221027101207-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>
<a href='https://seamarconi.com/en/newsblog/eurodoble-roma/attachment/img20221026092123-media_resized/'><img loading="lazy" decoding="async" width="150" height="150" src="https://seamarconi.com/wp-content/uploads/2022/10/IMG20221026092123-Media_resized-150x150.jpg" class="attachment-thumbnail size-thumbnail" alt="" /></a>

<p>&nbsp;</p>
<p>The post <a href="https://seamarconi.com/en/newsblog/eurodoble-roma/">Eurodoble Rome, a great opportunity for professional enrichment</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Comparison of Online DGA monitoring devices &#8211; Video now available</title>
		<link>https://seamarconi.com/en/newsblog/online-dga-monitoring-devices-nline-dga-monitoring-devices/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 06 Sep 2019 09:57:40 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[dissolved gases]]></category>
		<category><![CDATA[My Transfo]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=112765</guid>

					<description><![CDATA[<p>Following the suggestions of many people interested in we publisheb the the video recordings of the roundtable held the last My Transfo (Dec 2018). The main market players participated, including: Schröder Karsten – MTE (Germany), Pérez Marcos – General electric (Spain), Skelly Donal – Qualitrol Corporation (Ireland), Tozzi Marco – Camlin Power ltd (Italy), Mc Grail Tony – Doble (USA)</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/en/newsblog/online-dga-monitoring-devices-nline-dga-monitoring-devices/">Read more</a></p>
<p>The post <a href="https://seamarconi.com/en/newsblog/online-dga-monitoring-devices-nline-dga-monitoring-devices/">Comparison of Online DGA monitoring devices &#8211; Video now available</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Following the suggestions of many people interested in we publisheb the the video recordings of the roundtable held the last My Transfo (Dec 2018).</p>
<p>The main market players participated, including:</p>
<ul>
<li>Schröder Karsten – MTE (Germany),</li>
<li>Pérez Marcos – General electric (Spain),</li>
<li>Skelly Donal – Qualitrol Corporation (Ireland),</li>
<li>Tozzi Marco – Camlin Power ltd (Italy),</li>
<li>Mc Grail Tony – Doble (USA)</li>
<li>moderated by a true Transformer and switchyard expert, Mr Paulhiac Luc – EDF (FRANCE).</li>
</ul>
<p>Each of the participants expressed his point of view on three topics proposed by the moderator:</p>
<ol>
<li>different operating techniques,</li>
<li>calibration system,</li>
<li>maintenance needs,</li>
</ol>
<p>Given the excessive size of the video file, we published the roundtable divided into 3 parts, one for each topic.</p>
<p>&nbsp;</p>
<p style="text-align: center;"><strong><div class="boc_icon_holder boc_icon_size_normal boc_icon_pos_left  " style=""><span class="boc_icon icon icon-youtube-play" style="color:#333333;"></span></div> </strong>Watch the full videos <strong><a href="https://www.mytransfo.com/videogallery/">here</a></strong></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter size-medium" src="https://www.mytransfo.com/wp-content/uploads/2019/06/2_06-ROUND-TABLE-2-Online-DGA-Monitoring.png" width="1280" height="720" /></p>
<p>The post <a href="https://seamarconi.com/en/newsblog/online-dga-monitoring-devices-nline-dga-monitoring-devices/">Comparison of Online DGA monitoring devices &#8211; Video now available</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sea Marconi develops a new method for SF6 dissolved in oil</title>
		<link>https://seamarconi.com/en/newsblog/sea-marconi-develops-a-new-method-for-sf6-dissolved-in-oil/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 15 May 2012 14:43:54 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[SF6]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107805</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/newsblog/sea-marconi-develops-a-new-method-for-sf6-dissolved-in-oil/">Sea Marconi develops a new method for SF6 dissolved in oil</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi has developed and validated an innovative method for the determination of both normal dissolved gases (DGA) and <strong>SF6</strong> dissolved in mineral insulating oil.</p>
<p>Thanks to a very advanced instrumental configuration it is possible to identify in a punctual manner particular troubles that could occur in bushings with oil and SF6 separated by a membrane. Thus, the contamination by SF6 in the oil is a symptom of an evolving criticality, especially relevant for step-up transformers used in nuclear and thermal power plants.</p>
<p>The wide applicative case history allowed Sea Marconi to validate the method and statistically classify typical values of alert and alarm; in this manner it is possible to support the operational decisions of the Users to <strong>prevent or mitigate damages also of a catastrophic type (explosion and fires)</strong>. The new analytical method by Sea Marconi offers a specific response to those bearing the responsibility for the best management of fleets of equipment with insulating oils. Sea Marconi confirms being a leader, offering advanced, complete and reliable solutions in the activities for supporting the Life Cycle Management – LCM of transformers and related accessories.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-107805-288585570]" href="https://seamarconi.com/wp-content/uploads/2017/08/passantisf6_21.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="431" height="398" src="https://seamarconi.com/wp-content/uploads/2017/08/passantisf6_21.jpg" class="vc_single_image-img attachment-full" alt="" title="passantisf6_21" srcset="https://seamarconi.com/wp-content/uploads/2017/08/passantisf6_21.jpg 431w, https://seamarconi.com/wp-content/uploads/2017/08/passantisf6_21-300x277.jpg 300w" sizes="auto, (max-width: 431px) 100vw, 431px" /></a>
		</figure>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/newsblog/sea-marconi-develops-a-new-method-for-sf6-dissolved-in-oil/">Sea Marconi develops a new method for SF6 dissolved in oil</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>IEC 61181, new amendment for gas analysis (DGA) finalised toward factory tests</title>
		<link>https://seamarconi.com/en/newsblog/iec-61181-new-amendment-for-gas-analysis-dga-finalised-toward-factory-tests/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 15 May 2012 14:42:06 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[factory test]]></category>
		<category><![CDATA[dissolved gases]]></category>
		<category><![CDATA[IEC]]></category>
		<category><![CDATA[IEC 61181]]></category>
		<category><![CDATA[heating test]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107803</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/newsblog/iec-61181-new-amendment-for-gas-analysis-dga-finalised-toward-factory-tests/">IEC 61181, new amendment for gas analysis (DGA) finalised toward factory tests</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>February 2012, new amendment to norm IEC <strong><a href="http://webstore.iec.ch/webstore/webstore.nsf/Artnum_PK/46115">61181</a></strong> “Mineral oil-filled electrical equipment – <strong>Application of dissolved gas analysis (DGA) to factory tests on electrical equipment</strong>”.</p>
<p>This norm defines the <strong>criteria with which the analysis of gases is performed during factory tests</strong>, with particular attention for the heating tests. IEC 61181 goes into details over very specific topics, for example on sampling, the extraction of gases and the chromatographic test in the laboratory.</p>
<p>Sea Marconi offers an <strong>independent response from suppliers of transformers and oils</strong>, offering the most appropriate protocol, the analyses required, ensuring the best analytical and interpretative performances in accordance with IEC 61181.</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/newsblog/iec-61181-new-amendment-for-gas-analysis-dga-finalised-toward-factory-tests/">IEC 61181, new amendment for gas analysis (DGA) finalised toward factory tests</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>The Sea Marconi laboratory among the front runners in the RRT organised by ASTM</title>
		<link>https://seamarconi.com/en/newsblog/the-sea-marconi-laboratory-among-the-front-runners-in-the-rrt-organised-by-astm/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 07 Dec 2011 13:32:54 +0000</pubDate>
				<category><![CDATA[Accredia]]></category>
		<category><![CDATA[ASTM]]></category>
		<category><![CDATA[DGA]]></category>
		<category><![CDATA[dissolved gases]]></category>
		<category><![CDATA[RRT]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107754</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/newsblog/the-sea-marconi-laboratory-among-the-front-runners-in-the-rrt-organised-by-astm/">The Sea Marconi laboratory among the front runners in the RRT organised by ASTM</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The Sea Marconi analyses laboratory can be defined, without doubts, among the “front runners” after the results of two inter-laboratory tests (<strong>RRT – Round Robin Test or proficiency test</strong>) organised by <strong><a href="http://www.astm.org/index.shtml">ASTM </a></strong>International (USA).</p>
<p>The first RRT, in which Sea Marconi obtained <strong>extraordinary results</strong>, compared the quality of 65 laboratories on an international range in performing analytical tests on dissolved gases (<strong>DGA</strong>). In the second RRT, 87 laboratories were put in a contest in performing different physical-chemical tests (see Table below).</p>
<p>Both Round Robin Tests emphasised an absolute quality and a great competence by the Sea Marconi laboratory, thus confirming its role as international leader in the analytical tests of insulating fluids. For the accredited laboratories such as Sea Marconi’s. these RRT are essential to maintain the accreditation by <strong><a href="http://www.accredia.it/">Accredia</a></strong> (ex SINAL): in this instance obtained by Sea Marconi in February 2009 and extended in November 2010 and recently renewed.</p>
<p>To interpret correctly the data listed below, some information about these inter-laboratory tests is added. The RRT, also designated as proficiency tests, are an instrument ensuring the quality of the laboratories and the results of the analytical results issued. At the end of each RRT an evaluation is provided by a score system designated as “Z score”, the more this score is near to zero the better is the operation of the laboratory.</p>
<p>As a conclusion, in both the <strong>RRT the Sea Marconi laboratory has provided a great proof of force</strong>, by obtaining excellence scores both in absolute terms and in comparison with the laboratory worldwide. </p>

		</div>
	</div>
<h3 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Please find here below the results of the Proficiency test.</span></h3>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table id="tablepress-4" class="tablepress tablepress-id-4" width="100%">
<tbody>
<tr class="row-1">
<td class="column-1" colspan="8">Evaluation of tests on dissolved gases (DGA)</td>
</tr>
<tr class="row-2">
<td class="column-1"><span class="nome_prova">PT</span></td>
<td class="column-2">Parameter</td>
<td class="column-3">Results SMT</td>
<td class="column-4">Average value PT</td>
<td class="column-5">UdM</td>
<td class="column-6"><span class="nome_prova">Z-Score</span></td>
<td class="column-7">Result</td>
<td class="column-8">Accreditated test YES/NO</td>
</tr>
<tr class="row-3">
<td class="column-1" rowspan="11"><span class="nome_prova">ASTM PTP DGA1108</span></td>
<td class="column-2">Nitrogen</td>
<td class="column-3">73014</td>
<td class="column-4">60461</td>
<td class="column-5">?l/l</td>
<td class="column-6">1,3</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-4">
<td class="column-2">Oxygen</td>
<td class="column-3">36180</td>
<td class="column-4">28179</td>
<td class="column-5">?l/l</td>
<td class="column-6">1,5</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-5">
<td class="column-2">Carbon dioxide</td>
<td class="column-3">1477</td>
<td class="column-4">1455,4</td>
<td class="column-5">?l/l</td>
<td class="column-6">0,1</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-6">
<td class="column-2">Carbon monoxide</td>
<td class="column-3">11</td>
<td class="column-4">10,9</td>
<td class="column-5">?l/l</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-7">
<td class="column-2">Hydrogen</td>
<td class="column-3">2</td>
<td class="column-4">4,4</td>
<td class="column-5">?l/l</td>
<td class="column-6">-0,8</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-8">
<td class="column-2">Methane</td>
<td class="column-3">10</td>
<td class="column-4">10,5</td>
<td class="column-5">?l/l</td>
<td class="column-6">-0,2</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-9">
<td class="column-2">Ethane</td>
<td class="column-3">63</td>
<td class="column-4">59,6</td>
<td class="column-5">?l/l</td>
<td class="column-6">0,5</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-10">
<td class="column-2">Ethylene</td>
<td class="column-3">37</td>
<td class="column-4">34,6</td>
<td class="column-5">?l/l</td>
<td class="column-6">0,6</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-11">
<td class="column-2">Acetylene</td>
<td class="column-3">14</td>
<td class="column-4">12,5</td>
<td class="column-5">?l/l</td>
<td class="column-6">0,4</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-12">
<td class="column-2">Propane + propylene</td>
<td class="column-3">2</td>
<td class="column-4">0,5</td>
<td class="column-5">?l/l</td>
<td class="column-6">1,4</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-13">
<td class="column-2"></td>
<td class="column-3"></td>
<td class="column-4"></td>
<td class="column-5"></td>
<td class="column-6"></td>
<td class="column-7"></td>
<td class="column-8"></td>
</tr>
<tr class="row-14">
<td class="column-1" colspan="8">Insulating Fluid Quality – Evaluation of the physical- chemical tests</td>
</tr>
<tr class="row-15">
<td class="column-1"><span class="nome_prova">PT</span></td>
<td class="column-2">Parameter</td>
<td class="column-3">Results SMT</td>
<td class="column-4">Average value PT</td>
<td class="column-5"><span class="nome_prova">UdM</span></td>
<td class="column-6"><span class="nome_prova">Z-Score</span></td>
<td class="column-7">Result</td>
<td class="column-8">Accreditated test YES/NO</td>
</tr>
<tr class="row-16">
<td class="column-1" rowspan="18"><span class="nome_prova">TM PTP IFQ1109</span></td>
<td class="column-2">Acidity</td>
<td class="column-3">&lt; 0,01</td>
<td class="column-4">0,009</td>
<td class="column-5">mg/g</td>
<td class="column-6">-1,7</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-17">
<td class="column-2">Colour ASTM</td>
<td class="column-3">0,5</td>
<td class="column-4">&lt; 1,0 *</td>
<td class="column-5">&#8211;</td>
<td class="column-6">&#8211;</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-18">
<td class="column-2">Corr. Sulfur D 1275 A</td>
<td class="column-3">1b</td>
<td class="column-4">1b *</td>
<td class="column-5">&#8211;</td>
<td class="column-6">&#8211;</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-19">
<td class="column-2">Corr. Sulfur D 1275 B</td>
<td class="column-3">1b</td>
<td class="column-4">1b *</td>
<td class="column-5">&#8211;</td>
<td class="column-6">&#8211;</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-20">
<td class="column-2">2-FAL</td>
<td class="column-3">1</td>
<td class="column-4">1</td>
<td class="column-5">?g/kg</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-21">
<td class="column-2">2-FOL</td>
<td class="column-3">assente</td>
<td class="column-4">assente</td>
<td class="column-5">?g/kg</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-22">
<td class="column-2">5-MEF</td>
<td class="column-3">assente</td>
<td class="column-4">assente</td>
<td class="column-5">?g/kg</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-23">
<td class="column-2">5-HMF</td>
<td class="column-3">assente</td>
<td class="column-4">assente</td>
<td class="column-5">?g/kg</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-24">
<td class="column-2">2-ACF</td>
<td class="column-3">assente</td>
<td class="column-4">assente</td>
<td class="column-5">?g/kg</td>
<td class="column-6">0</td>
<td class="column-7">Good</td>
<td class="column-8">YES</td>
</tr>
<tr class="row-25">
<td class="column-2">IFT</td>
<td class="column-3">41,5</td>
<td class="column-4">44,33</td>
<td class="column-5">mN/m</td>
<td class="column-6">-1</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-26">
<td class="column-2">DBPC</td>
<td class="column-3">0,36</td>
<td class="column-4">0,287</td>
<td class="column-5">% m/m</td>
<td class="column-6">1,4</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-27">
<td class="column-2">Particles &gt; 4 ?m</td>
<td class="column-3">307</td>
<td class="column-4">399,77</td>
<td class="column-5">n°/ml</td>
<td class="column-6">-0,2</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-28">
<td class="column-2">Particles &gt; 6 ?m</td>
<td class="column-3">71</td>
<td class="column-4">109,19</td>
<td class="column-5">n°/ml</td>
<td class="column-6">-0,4</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-29">
<td class="column-2">Particles &gt; 14 ?m</td>
<td class="column-3">7</td>
<td class="column-4">11,86</td>
<td class="column-5">n°/ml</td>
<td class="column-6">-0,5</td>
<td class="column-7">Good</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-30">
<td class="column-2">Pour Point</td>
<td class="column-3">-63</td>
<td class="column-4">-56,1</td>
<td class="column-5">°C</td>
<td class="column-6">-1,8</td>
<td class="column-7">Satisfactory</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-31">
<td class="column-2">Density</td>
<td class="column-3">0,8877</td>
<td class="column-4">0,89315</td>
<td class="column-5">g/ml</td>
<td class="column-6">&lt; -3</td>
<td class="column-7">Unsatisfactory</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-32">
<td class="column-2">Kinematic viscosity 40°C</td>
<td class="column-3">9,37</td>
<td class="column-4">8,865</td>
<td class="column-5">cSt</td>
<td class="column-6">&gt; 3</td>
<td class="column-7">Unsatisfactory</td>
<td class="column-8">NO</td>
</tr>
<tr class="row-33">
<td class="column-2">Water in oil</td>
<td class="column-3">27</td>
<td class="column-4">36,8</td>
<td class="column-5">mg/kg</td>
<td class="column-6">-2,2</td>
<td class="column-7">Questionable</td>
<td class="column-8">YES</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>* mode (most frequent value)</p>
<p>Among the 28 tests under exam, only the parameters for density and kinematic viscosity didn’t obtain Z scores complying with the majority of the participating laboratories.<br />
To investigate the causes of this discrepancy, the laboratory has already implemented the internal quality procedures that shall result shortly in a corrective action. The tests for water, having a questionable result, shall be soon under evaluation again, thus more elements on this subject are going to be obtained. All the other Z scores have pointed out a great professionalism by the Sea Marconi laboratory, with points of excellence in the determination of gases and furans.</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/newsblog/the-sea-marconi-laboratory-among-the-front-runners-in-the-rrt-organised-by-astm/">The Sea Marconi laboratory among the front runners in the RRT organised by ASTM</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>New international accreditation of the Sea Marconi analysis and research laboratory</title>
		<link>https://seamarconi.com/en/newsblog/new-international-accreditation-of-the-sea-marconi-analysis-and-research-laboratory/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 14 Jan 2011 17:05:56 +0000</pubDate>
				<category><![CDATA[accreditation]]></category>
		<category><![CDATA[oil analysis]]></category>
		<category><![CDATA[auditing]]></category>
		<category><![CDATA[DGA]]></category>
		<category><![CDATA[diagnosis]]></category>
		<category><![CDATA[insulating oil]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107662</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/en/newsblog/new-international-accreditation-of-the-sea-marconi-analysis-and-research-laboratory/">New international accreditation of the Sea Marconi analysis and research laboratory</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"></div>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>After the accreditation of the test of PCBs in February 2009, Sea Marconi has obtained last November 2010 from <strong><a href="http://www.accredia.it/">ACCREDIA</a></strong> a brilliant confirmation, by <strong>extending the accreditation</strong> to the tests of <strong>dissolved gases (DGA</strong>*, <strong>dissolved water</strong> and <strong>furanic compounds</strong>)* (see here below the detail of the accredited tests).</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Created form the combination of SINAL and SINCERT, <strong>ACCREDIA</strong> is the only organism authorised by the Italian State to perform accreditation activities.</p>
<p>Once more the work of the Accredia inspectors in Sea Marconi, was not limited exclusively to a scrupulous evaluation of the technical and organisational procedures of the laboratory, but also to a keen check of the qualification of human and instrumental resources in all the areas of the company involved in the testing and calibration activities.</p>
<p><strong>With this additional accreditation, the Sea Marconi laboratory becomes one among very few laboratories worldwide (the only one in Italy) able to offer a package of accredited tests fundamental in the diagnosis of electrical equipment with insulating fluids.</strong></p>
<p>&nbsp;</p>
<div align="justify"><strong><a href="http://pa.sinal.it/PA1132AR2.PDF">Download here the pdf with the list of tests</a>,</strong> with the indication of the matrices, the norms and methods applied (revision 2 of 23<sup>rd</sup> November 2010).</div>
<div align="justify"></div>
<div align="justify">The participation of ACCREDIA to the Multilateral Agreements for the Mutual Recognition (MLA) is such that the test and inspection reports issued by Sea Marconi relative to accredited tests, are <strong>recognised and accepted at international level</strong> by all nations that signed the mutual <strong>recognition agreements </strong>(<strong><a href="http://www.european-accreditation.org/content/mla/scopes.htm">list of EA Countries</a></strong> (European Accreditation);<strong> </strong>and<strong> list of IAF Countris</strong> (International Accreditation Forum)).</div>
<p>Thus, the accreditation brand on the Sea Marconi’s test report “<em>operates as a passport on international markets, where the holder is not required to have its product, service or its professionalism subject to additional tests, inspections or verifications</em>” [web site Accredia, page International Agreements pag. <a href="http://www.accredia.it/context.jsp?ID_LINK=66&amp;area=6"><strong>Accordi internazionali</strong></a>].</p>
<p>The accreditation of the single tests ensures that Sea Marconi’s laboratory on one side is fully complying with the analysis procedures and methods on the single matrices and in particular with the requisites of standard ISO IEC 17025 relative to the uncertainty of measurement, on the other side that it implements a constant monitoring of the performances also with the participation to international inter-laboratories circuits (RRT – Round Robin Test or Proficiency Test) <strong>achieving scores (Z score) of absolute excellency</strong>.</p>
<p>Thus, the Sea Marconi test report gets a specific relevance in legal terms, when required, and a full compliance with the Directives, implementation Laws or Technical standards of the sector (IEC, CENELEC, CEI, etc.) ensuring an independent and expert evaluation of the domain (since 1968, with 42 years of activity in over 30 Countries). The Sea Marconi test report, together with the other evaluation parameters, is dynamically interpreted (with the diagnostic algorithms and the Sea Marconi data bank on over 60,000 equipment) to ensure the best diagnostic coverage for the management of the life cycle (Life Cycle Management – LCM) of <strong>fleets of equipment with insulating fluids</strong>, strategic units in the generation, transportation, distribution and use of energy.Sea Marconi operates for the prevention of damages through the classification of the type and priorities of the functional and environmental criticalities as well as the correlated countermeasures to prevent and/or mitigate risks.</p>
<p>Sea Marconi opera per la <strong>prevenzione dei danni</strong> attraverso la classificazione del tipo e priorità delle criticità funzionali e/o ambientali nonché delle correlate contromisure per prevenire e/o mitigare i rischi.</p>
<p>*Complete list of the tests (6) in revision 2 of 23-11-2010</p>
<p>An asterisk in the first column indicates that, for the corresponding test, the Laboratory has discontinued the issue of reports with the SINAL brand.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table style="width: 100%; background-color: white; background-position: initial initial; background-repeat: initial initial;" border="0" cellspacing="0" cellpadding="0">
<thead>
<tr>
<td style="width: 18.15pt; background: #004258; border: #d4d0c8; padding: 2.4pt 4.8pt 2.4pt 4.8pt;" width="24">
<div style="text-align: left; line-height: normal;" align="left"><strong><span style="color: white; font-size: 9pt;">S.</span></strong></div>
<p>&nbsp;</td>
<td style="width: 25.85pt; background: #004258; border: #d4d0c8; padding: 2.4pt 4.8pt 2.4pt 4.8pt;" width="34">
<div style="text-align: left; line-height: normal;" align="left"><strong><span style="color: white; font-size: 9pt;">Cat.</span></strong></div>
<p>&nbsp;</td>
<td style="width: 109.8pt; background: #004258; border: #d4d0c8; padding: 2.4pt 4.8pt 2.4pt 4.8pt;" width="146">
<div style="text-align: left; line-height: normal;" align="left"><strong><span style="color: white; font-size: 9pt;">Material / product / matrix</span></strong></div>
<p>&nbsp;</td>
<td style="width: 217pt; background: #004258; border: #d4d0c8; padding: 2.4pt 4.8pt 2.4pt 4.8pt;" width="289">
<div style="text-align: left; line-height: normal; text-indent: 84.85pt; margin: 0cm 0cm 0pt -84.85pt;" align="left"><strong><span style="color: white; font-size: 9pt;">Designation of the test</span></strong></div>
<p>&nbsp;</td>
<td style="width: 151pt; background: #004258; border: #d4d0c8; padding: 2.4pt 4.8pt 2.4pt 4.8pt;" width="201">
<div style="text-align: left; line-height: normal;" align="left"><strong><span style="color: white; font-size: 9pt;">Norm/test method</span></strong></div>
<p>&nbsp;</td>
</tr>
</thead>
<tbody>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Insulating liquids</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; width: 217pt; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">2-Furfural and derivative compounds- 2-FAL (2-furfuraldehyde) – 5-HMF (5-hyidrossimetil-2-furfuraldehyide) – 5-MEF (5-metil-2-furfuraldehyde) – 2-FOL (2-furfurlalchool) – 2-ACF (2-acetilfuran) (&gt; 0,05 mg/kg)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">IEC 61198:1993-09</span></div>
<p>&nbsp;</td>
</tr>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Insulating liquids</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; width: 217pt; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Dissolved water (&gt; 2 mg/kg)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">IEC 60814:1997-08 (excluding points 2 e 4)</span></div>
<p>&nbsp;</td>
</tr>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Insulating liquids</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; width: 217pt; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Polychlorinated biphenyls (PCBs) Policlorobifenilos (PCB) (&gt; 2 mg/kg)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">IEC 61619:1997-04, CEI EN 61619:1998-11</span></div>
<p>&nbsp;</td>
</tr>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Insulating oils</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; width: 217pt; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Dissolved gases in oil (head space): – Oxygen(O2) – Nitrogen (N2) –Carbon dioxide (CO2) – Carbon monoxide (CO) – Hydrogen (H2) – Methane (CH4) – Ethane (C2H6) – Ethylene (C2H4) – Acetylene (C2H2) (Oxygen: &gt; 500)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">IEC 60567:2005-06 (excluding points 3 and 4; extraction technique: head space point 7.5)</span></div>
<p>&nbsp;</td>
</tr>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Mineral Insulating oils</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; width: 217pt; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Total PCBs (&gt; 10 mg/kg)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background-color: transparent; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">D.Lgs. n° 209 22/05/1999 GU n° 151 30/06/1999, Dir CE 59/1996 GUCE L243 24/09/1996, EEC Directive 59/1996 GU CE L243 24/09/1996</span></div>
<p>&nbsp;</td>
</tr>
<tr>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top"></td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">0</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">New, used, treated petroleum products; Synthetic or recovered lubricants; mixtures of vegetable oils.</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; width: 217pt; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top" width="289">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">Policlorotrifenili (PCT) Policlorobenziltolueni (PCBT) Polychloroterphéniles (PCT), Polychlorobenzyltoluènes (PCBT) Polychlorinated terphenyls (PCT), Polychlorinated benzyl toluenes (PCBT), Policlorofenilo (PCT), Policlorobencitolueno (PCBT) (PCBT: &gt; 5 mg/kg PCT: &gt; 10 mg/kg)</span></div>
<p>&nbsp;</td>
<td style="border-bottom: #ededed 1pt solid; border-left: #d4d0c8; background: #ededed; border-top: #d4d0c8; border-right: #dddddd 1pt solid; padding: 6pt;" valign="top">
<div style="text-align: left; line-height: normal;" align="left"><span style="font-size: 8.5pt;">EN 12766-3:2004, UNI EN 12766-3:2005</span></div>
<p>&nbsp;</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Read more:</p>
<ul>
<li><a href="http://www.accredia.it/accredia_labsearch.jsp?ID_LINK=293&amp;area=7"><strong>Search of the laboratories accredited ACCREDIA</strong></a></li>
<li><a href="http://www.european-accreditation.org/"><strong>EA</strong></a> (European Accreditation)</li>
<li><strong><a href="http://www.iaf.nu/">IAF</a></strong> (International Accreditation Forum)</li>
</ul>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/en/newsblog/new-international-accreditation-of-the-sea-marconi-analysis-and-research-laboratory/">New international accreditation of the Sea Marconi analysis and research laboratory</a> appeared first on <a href="https://seamarconi.com/en">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
