<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Argile smectique Archives - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/fr/tag/argile-smectique/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/tag/terre-follari/</link>
	<description>Sea Marconi soutient dans la gestion des transformateurs contenant des huiles isolantes</description>
	<lastBuildDate>Fri, 06 Mar 2020 07:37:47 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>Élimination du soufre corrosif des sous-produits de la combustion du soufre (C3)  Uruguay 2010</title>
		<link>https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-des-sous-produits-de-la-combustion-du-soufre-c3-uruguay-2010/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:51:16 +0000</pubDate>
				<category><![CDATA[C3]]></category>
		<category><![CDATA[sous-produits de soufre]]></category>
		<category><![CDATA[Argile smectique]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4207</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-des-sous-produits-de-la-combustion-du-soufre-c3-uruguay-2010/">Élimination du soufre corrosif des sous-produits de la combustion du soufre (C3) &lt;strong&gt; Uruguay 2010&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Uruguayan utility</p>
<p><strong>October 2012: Failure</strong> 2 weeks after a reclaim treatment with fuller earth (performed by a local operator).</p>
<p>Nameplate data of the transformer:</p>
<p>Transformer: grid transformer with OLTC<br />
Manufact.: xxx<strong><br />
</strong>Year:<strong> 1977<br />
</strong>Power [MVA]: <strong>425<br />
</strong>Voltage [KV]: <strong>500<br />
</strong>Oil mass [Kg]: <strong>58.000<br />
</strong>Oil type: YPF65 <strong>paraffinic oil not inhibited</strong></p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4207-1400619256]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso14_segni-di-arco-e1445251531144.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="379" height="247" src="https://seamarconi.com/wp-content/uploads/2013/05/caso14_segni-di-arco-e1445251531144.jpg" class="vc_single_image-img attachment-full" alt="" title="caso14_segni-di-arco-e1445251531144" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso14_segni-di-arco-e1445251531144.jpg 379w, https://seamarconi.com/wp-content/uploads/2013/05/caso14_segni-di-arco-e1445251531144-300x196.jpg 300w" sizes="(max-width: 379px) 100vw, 379px" /></a><figcaption class="vc_figure-caption">Segni di arco elettrico sui contatti del selettore</figcaption>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Analysis and diagnosis (by the holder)</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The diagnosis of the holder, as a result of the field tests, presumed an high energy discharge in the main tank. Subsequently, after laboratory tests, was discovered a <strong>failure in the OLTC</strong> that produced a discharge in the transformer main tank.</p>
<p>The reclaim treatment with fuller earth made the oil aggressive towards the silver surfaces of the contacts.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4207-4198532166]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso14_contatti_argento.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="423" height="223" src="https://seamarconi.com/wp-content/uploads/2013/05/caso14_contatti_argento.jpg" class="vc_single_image-img attachment-full" alt="" title="caso14_contatti_argento" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso14_contatti_argento.jpg 423w, https://seamarconi.com/wp-content/uploads/2013/05/caso14_contatti_argento-300x158.jpg 300w" sizes="(max-width: 423px) 100vw, 423px" /></a><figcaption class="vc_figure-caption">Corrosione della superficie in argento dei contatti</figcaption>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Analysis, diagnosis and expertise by Sea Marconi</span></h2>
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4207-1496033828]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso14_trattamento_terre.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="327" height="185" src="https://seamarconi.com/wp-content/uploads/2013/05/caso14_trattamento_terre.jpg" class="vc_single_image-img attachment-full" alt="" title="caso14_trattamento_terre" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso14_trattamento_terre.jpg 327w, https://seamarconi.com/wp-content/uploads/2013/05/caso14_trattamento_terre-300x170.jpg 300w" sizes="(max-width: 327px) 100vw, 327px" /></a><figcaption class="vc_figure-caption">Columns with reactivated earths (not used by Sea Marconi)</figcaption>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element bq_yellow" >
		<div class="wpb_wrapper">
			<blockquote><p>
«A<em>t relatively high temperature, sulphur-containing oil molecules may decompose and react with metal surface to form metal sulphides</em>» (IEC 60422 Ed. 4 – 2013 art. 5.17)
</p></blockquote>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi calls this case as <strong>SCBP</strong> <strong>(Sulfur Combustion ByProducts) &amp; Corrosive Sulfur</strong>.</p>
<p>“<em>The oil regeneration process plant involves the high temperature reactivation of sorbent and fuller earth column by uncontrolled combustion. The Sulfur Compounds naturally present (DiBenzoThioPhene – DBTP, etc.) in the Oil and additives (DBDS, etc.) are decomposed in Sulfur Combustion ByProducts (such as corrosive H2S, Mercaptans, etc.) forming Sulphides CuS, Cu2S, Ag2S, etc.</em>”. Ref. other case histories such as National Grid, ABB, etc.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h4>Analytical results</h4>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>CCD</strong></td>
<td style="text-align: center;" valign="top"><strong><b>Corrosive</b></strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TCS </strong>DBDS Eq.<strong> </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>131</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>ASTM 1275 B</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>4C</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DBTP </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><strong>24</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><strong>0,01</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong><b>DF</b></strong></td>
<td style="text-align: center;" valign="top"><b>0,018</b></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong><b>IFT </b></strong>[mN/m]</td>
<td style="text-align: center;" valign="top"><b>0,018</b></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-des-sous-produits-de-la-combustion-du-soufre-c3-uruguay-2010/">Élimination du soufre corrosif des sous-produits de la combustion du soufre (C3) &lt;strong&gt; Uruguay 2010&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</title>
		<link>https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 16 Apr 2013 08:23:17 +0000</pubDate>
				<category><![CDATA[huile]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[sous-produits de soufre]]></category>
		<category><![CDATA[Argile smectique]]></category>
		<category><![CDATA[transformateur]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107909</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/">Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="qtranxs-available-languages-message qtranxs-available-languages-message-fr">La traduction en français est en cours. Si vous visitez le site dans quelques jours, il sera intégralement en français. En attendant, vous pouvez visualiser le site en <a href="https://seamarconi.com/it/tag/terre-follari/" class="qtranxs-available-language-link qtranxs-available-language-link-it" title="Italiano">Italiano</a> ou en <a href="https://seamarconi.com/en/tag/fuller-hearth/" class="qtranxs-available-language-link qtranxs-available-language-link-en" title="English">English</a>. Si vous visitez le site dans quelques jours, il sera intégralement en français. En attendant, vous pouvez visualiser le site en italien ou en anglais.</p><div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Analyse comparative entre les différentes traitements disponibles pour la gestion du cycle de vie des huiles et transformateurs</span></h3>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Télécharger le PDF: <a title="Download Trattamenti Sea Marconi vs Terre follari ITA" href="https://seamarconi.com/wp-content/uploads/2017/09/Scheda-trattamenti-integrati-e-DMU-vs-terre-follari_ITA.pdf" target="_blank" rel="noopener noreferrer"><b>Trattamenti Sea Marconi vs Terre follari ITA</b></a> (379.5 KiB)</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table style="width: 100%;" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td>
<div align="center"><b>FACTEURS CLE</b></div>
</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"><strong><b>DMU &amp; Traitements intégrés* Brevets Sea Marconi</b><br />
</strong></span></span></div>
</td>
<td>
<div align="center">Traitement par terres à foulons classique</div>
</td>
<td>
<div align="center">Traitement par terres à foulons avec régénération à T° &gt; 600-700 °C</div>
</td>
</tr>
<tr>
<td><b>Récupération : propriétés physiques :</b>KV, Gas dissous, H<sub>2</sub>O</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #339966;">Oui</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Récupération : propriétés chimiques : </b>Acidité, Facteur de dissipation, Tension interfaciale</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #339966;">Oui</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Décontamination : DBDS &amp; Soufres corrosifs  (cas C1 à C4)</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #ff0000;">Non</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Decontamination: Métaux en solution</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Déhalogenation : PCB</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Classification: BAT/BEP </b>– Meilleure technologie disponible , Best Practices (PCBs/POPs)</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Self-cleaning de l’unité : DBDS, PCBs/POPs</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Contamination croisée par DBDS,  PCBs/POPs</b></td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <b>Sécurité</b></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Corrosion par sous-produits de dégradation du soufre (SDBP)</b><b></b>comme  H<sub>2</sub>S, Mercaptans, etc. causée par température élevée (&gt; 370 °C – typiques 600-700 °C)</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Risques de Formation de Dioxines (PCDDs, PCDFs)</b><b> </b>lors de l’étape de regeneration à Haute T° dans le cas des huiles contaminées par PCB PCT PCBT</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>*<strong>CDP Process<sup>®</sup></strong> for PCBs/POPs chemical dehalogenation; <strong>CHEDCOS</strong> for DBDS &amp; Corrosive Sulfur Selective Depolarization</p>

		</div>
	</div>
<h2 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Cas «C3 – SDBP** et soufre corrosif»</span></h2><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>URUGUAY 2010</span></h3></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="379" height="304" src="https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco.jpg" class="vc_single_image-img attachment-full" alt="Segni di arco elettrico sui contatti del selettore" title="Segni di arco elettrico sui contatti del selettore" srcset="https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco.jpg 379w, https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco-300x241.jpg 300w" sizes="auto, (max-width: 379px) 100vw, 379px" /></div><figcaption class="vc_figure-caption">Segni di arco elettrico sui contatti del selettore</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><i>Le diagnostic post-avarie sur le Transformer a montré des <b>signes d’arcs électriques</b> sur les contacts sélecteur de prises. L’avarie a été <b>causée par la formation de sulfures de Cuivre/Ag</b>,  tels que  CuS, Cu<sub>2</sub>S, Ag<sub>2</sub>S, etc. En effet, «</i><i>à relativement haute température, les molécules d’huile contenant du soufre peuvent se décomposer et réagissent avec la surface métallique pour former des sulfures métalliques</i>”  (IEC 60422 éd. 4 – 2013 Art 5,17). Ce mécanisme à eu lieu lors du processus de régénération de l’huile à l’étape de réactivation de la colonne de terres par la combustion non contrôlée (&gt; 370 ° C). Les composés sulfurés présents naturellement dans l’huile, ainsi que les additifs (Dibenzothiophene – DBTP, etc) (DBDS, etc), sont alors décomposés en **<b>sous-produits de dégradation du soufre</b>. Autres cas typiques : National Grid Ref (UK), ABB (Suède), 2010 Conférence Doble (USA)</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Soluzioni sostenibili Sea Marconi – Valore aggiunto per i clienti, detentori e partners:</span></h3>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li><b>45 ans d’innovation</b> pour la gestion du cycle de vie des huiles et des transformateurs.</li>
<li>Des solutions basées sur l’approche globale et intégrée, les case history, l’état de l’art, les normes <b>CEI</b>, les lignes directrices du <b>CIGRE</b>, la Convention de Stockholm sur les POP (polluants organiques persistants).</li>
<li>Solutions pour la prévention et / ou atténuation des pertes et des risques pour les actifs, les travailleurs, la santé publique et l’environnement.</li>
<li>Focus sur des problématiques prioritaires  pour les équipements électriques en huiles isolantes. <b>Diagnostic</b> (&gt; 150.000 cas) et des traitements intégrés (&gt; 700 transformateurs de puissance – 2012 par <b>Unité mobile</b>, garantissent une expertise indépendante, la fiabilité, le contrôle de la qualité (ISO 9001-2008, ACCREDIA ISO 17025), la traçabilité, les avantages économiques et environnementaux.</li>
</ul>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/">Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>