<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>huile isolante Archives - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/fr/tag/huile-isolante/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/tag/olio-isolante/</link>
	<description>Sea Marconi soutient dans la gestion des transformateurs contenant des huiles isolantes</description>
	<lastBuildDate>Fri, 20 Mar 2026 11:28:47 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.1</generator>
	<item>
		<title>My Transfo on the Road arrive à Lyon : un nouveau chapitre local pour le partage des connaissances techniques</title>
		<link>https://seamarconi.com/fr/newsblog/my-transfo-on-the-road-arrive-a-lyon-un-nouveau-chapitre-local-pour-le-partage-des-connaissances-techniques/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Thu, 29 Jan 2026 15:02:26 +0000</pubDate>
				<category><![CDATA[DGA]]></category>
		<category><![CDATA[diagnostic]]></category>
		<category><![CDATA[gestion du cycle de vie]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=120963</guid>

					<description><![CDATA[<p>&#160; My Transfo on the Road est l’extension locale de la conférence internationale My Transfo, organisée par Sea Marconi depuis 2002. Après plus de vingt ans de dialogue technique à l’échelle internationale, l’expérience My Transfo se rapproche des marchés locaux grâce à un format professionnel concentré sur une journée. La première étape de cette nouvelle initiative aura lieu à Lyon</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/fr/newsblog/my-transfo-on-the-road-arrive-a-lyon-un-nouveau-chapitre-local-pour-le-partage-des-connaissances-techniques/">En savoir plus</a></p>
<p>The post <a href="https://seamarconi.com/fr/newsblog/my-transfo-on-the-road-arrive-a-lyon-un-nouveau-chapitre-local-pour-le-partage-des-connaissances-techniques/">My Transfo on the Road arrive à Lyon : un nouveau chapitre local pour le partage des connaissances techniques</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><img fetchpriority="high" decoding="async" class="aligncenter size-full wp-image-120964" src="https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma.png" alt="" width="1201" height="627" srcset="https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma.png 1201w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-300x157.png 300w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-1024x535.png 1024w, https://seamarconi.com/wp-content/uploads/2026/01/visual_linkedin_otRfra_banner-firma-768x401.png 768w" sizes="(max-width: 1201px) 100vw, 1201px" /></p>
<p>&nbsp;</p>
<p>My Transfo on the Road est l’extension locale de la conférence internationale <a href="https://www.mytransfo.com/?lang=fr" target="_blank" rel="noopener"><strong>My Transfo</strong></a>, organisée par Sea Marconi depuis 2002. Après plus de vingt ans de dialogue technique à l’échelle internationale, l’expérience My Transfo se rapproche des marchés locaux grâce à un format professionnel concentré sur une journée.</p>
<p>La première étape de cette nouvelle initiative aura lieu à <a href="https://www.mytransfo.com/my-transfo-on-the-road/my-transfo-on-the-road-2026-lyon/?lang=fr"><strong>Lyon le 10 juin 2026</strong></a>, avec un événement entièrement en français dédié aux transformateurs et aux fluides isolants.</p>
<p>My Transfo on the Road est conçu pour apporter aux marchés locaux les solutions, les compétences et le savoir développés au sein de la conférence internationale My Transfo. Les connaissances issues des plus grands experts internationaux intervenant à My Transfo sont transférées et mises au service des contextes locaux à travers le format My Transfo on the Road.</p>
<h3>Un format concentré à forte valeur technique</h3>
<p>L’édition lyonnaise propose un programme intensif d’une journée, pensé pour optimiser le temps et la valeur professionnelle des participants. Les thématiques en cours de définition incluent le prélèvement d’échantillons de liquides isolants, les pathologies d’hydratation des transformateurs, la diagnostic des fluides isolants, les phénomènes de stray water, la réhabilitation des parcs de transformateurs, la gestion des données de laboratoire et les bonnes pratiques d’essais électriques.</p>
<p>L’événement réunit un réseau local qualifié composé de utilities, d’ingénieurs, de laboratoires, de fabricants et d’experts techniques, favorisant un échange direct autour de problématiques opérationnelles concrètes.</p>
<h3>Un événement local, fidèle à la vision My Transfo</h3>
<p>My Transfo on the Road conserve les principes fondateurs de la plateforme My Transfo : partage des connaissances, rigueur scientifique, indépendance des contenus et lien étroit entre recherche et expérience terrain. Le format local permet d’exprimer ces valeurs dans la langue nationale et dans un contexte régional.</p>
<p>Avec Lyon 2026, Sea Marconi inaugure la première étape d’une feuille de route plus large qui étendra My Transfo on the Road à d’autres marchés européens et internationaux. La deuxième étape est d’ores et déjà prévue à <strong>Madrid en octobre 2026</strong>.</p>
<p>The post <a href="https://seamarconi.com/fr/newsblog/my-transfo-on-the-road-arrive-a-lyon-un-nouveau-chapitre-local-pour-le-partage-des-connaissances-techniques/">My Transfo on the Road arrive à Lyon : un nouveau chapitre local pour le partage des connaissances techniques</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Treatment Technologies for Transformers’ Corrosive Sulphur &#8211; A great saudi workshop by GCC Lab and Sea Marconi</title>
		<link>https://seamarconi.com/fr/newsblog/treatment-technologies-for-transformers-corrosive-sulphur-a-great-saudi-workshop-by-gcc-lab-and-sea-marconi/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 30 Sep 2022 13:42:05 +0000</pubDate>
				<category><![CDATA[DBDS]]></category>
		<category><![CDATA[NON DBDS]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=115753</guid>

					<description><![CDATA[<p>We are very honored to have participated in the workshop “Treatment Technologies for Transformers’ Corrosive Sulphur” organized by our saudi partner GCC Lab in Damman (Saudi Arabia) the 26 and 27 Sept. 2022.  The event was attended by 50 engineers/technicians from different clients of GCC Lab and was focused on Asset Integrity Management. Sea Marconi attended the event with 4 very high profile speakers: Cristina Tumiatti (Global Business Development Director),</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/fr/newsblog/treatment-technologies-for-transformers-corrosive-sulphur-a-great-saudi-workshop-by-gcc-lab-and-sea-marconi/">En savoir plus</a></p>
<p>The post <a href="https://seamarconi.com/fr/newsblog/treatment-technologies-for-transformers-corrosive-sulphur-a-great-saudi-workshop-by-gcc-lab-and-sea-marconi/">Treatment Technologies for Transformers’ Corrosive Sulphur &#8211; A great saudi workshop by GCC Lab and Sea Marconi</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>We are very honored to have participated in the workshop “<a href="https://www.linkedin.com/posts/gcclab_gccabrlab-activity-6980518295992958976-bj06/?utm_source=share&amp;utm_medium=member_desktop" target="_blank" rel="noopener noreferrer"><strong>Treatment Technologies for Transformers’ Corrosive Sulphur</strong></a>” organized by our saudi partner <a href="https://gcclab.com.sa/" target="_blank" rel="noopener noreferrer"><strong>GCC Lab</strong></a> in Damman (Saudi Arabia) the <sup>26</sup> and <sup>27</sup> Sept. 2022.  The event was attended by 50 engineers/technicians from different clients of <strong>GCC Lab</strong> and was focused on Asset Integrity Management.</p>
<p>Sea Marconi attended the event with 4 very high profile <strong>speakers</strong>: Cristina Tumiatti (Global Business Development Director), Riccardo Actis (Chief Operation Manager), Riccardo Maina (laboratory manager), Simone Maina (project manager) confirming its international leadership on the corrosive sulfur issue in oils and electrical transformers.</p>
<p style="text-align: center;"><img decoding="async" class="aligncenter size-full wp-image-115755" src="https://seamarconi.com/wp-content/uploads/2022/09/2022-09-30-15_40_34-87-Pubblica-_-LinkedIn.png" alt="" width="734" height="409" srcset="https://seamarconi.com/wp-content/uploads/2022/09/2022-09-30-15_40_34-87-Pubblica-_-LinkedIn.png 734w, https://seamarconi.com/wp-content/uploads/2022/09/2022-09-30-15_40_34-87-Pubblica-_-LinkedIn-300x167.png 300w" sizes="(max-width: 734px) 100vw, 734px" /></p>
<p>The post <a href="https://seamarconi.com/fr/newsblog/treatment-technologies-for-transformers-corrosive-sulphur-a-great-saudi-workshop-by-gcc-lab-and-sea-marconi/">Treatment Technologies for Transformers’ Corrosive Sulphur &#8211; A great saudi workshop by GCC Lab and Sea Marconi</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Est disponible le premier jet de l&#8217;agenda de My Transfo 2018</title>
		<link>https://seamarconi.com/fr/newsblog/est-disponible-le-premier-jet-de-lagenda-de-my-transfo-2018/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Thu, 09 Aug 2018 08:08:11 +0000</pubDate>
				<category><![CDATA[Autre]]></category>
		<category><![CDATA[conférence]]></category>
		<category><![CDATA[formation et formation]]></category>
		<category><![CDATA[huile]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[transformateur]]></category>
		<guid isPermaLink="false">https://www.mytransfo.com/?p=5375</guid>

					<description><![CDATA[<p>Est disponible le premier jet de l&#8217;agenda, à travers lequel il est possible d&#8217;avoir une idée des sujets qui seront discutés dans le prochain My Transfo 2018: Solid and liquid insulating materials for high temperature, applications and case histories &#62;&#62; Richard Marek – Dupont (USA) Characterization of different cellulose types using dielectric frequency response (FDS) &#62;&#62; Britta Pfeiffer – Omicron (Austria) Increasead</p>
<div class="h10"></div>
<p><a class="more-link1" href="https://seamarconi.com/fr/newsblog/est-disponible-le-premier-jet-de-lagenda-de-my-transfo-2018/">En savoir plus</a></p>
<p>The post <a href="https://seamarconi.com/fr/newsblog/est-disponible-le-premier-jet-de-lagenda-de-my-transfo-2018/">Est disponible le premier jet de l&#8217;agenda de My Transfo 2018</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Est disponible le premier jet de l&#8217;agenda, à travers lequel il est possible d&#8217;avoir une idée des sujets qui seront discutés dans le prochain My Transfo 2018:</p>
<p><strong>Solid and liquid insulating materials for high temperature, applications and case histories</strong><br />
&gt;&gt; Richard Marek – Dupont (USA)<br />
<strong>Characterization of different cellulose types using dielectric frequency response (FDS)</strong><br />
&gt;&gt; Britta Pfeiffer – Omicron (Austria)<br />
<strong>Increasead Loadability of Transformers Immersed in Natural Esters</strong><br />
&gt;&gt; Fabio Scatiggio – Terna (Italy)<br />
<strong><br />
Round Table on “Natural esters” with</strong><br />
&gt;&gt; to be defined – A&amp;A Fratelli Parodi (Italy)<br />
&gt;&gt; Kevin Rapp – Cargill (USA)<br />
&gt;&gt; to be defined<br />
&gt;&gt; Russel Martin – M&amp;I (UK)<br />
Moderated by Fabio Scatiggio* – Terna (Italy)</p>
<p><strong>Degradation phenomena of natural esters</strong><br />
&gt;&gt; Riccardo Maina – Sea Marconi (Italy)<br />
<strong>Qualification of Insulating Liquids for Tap-Changers</strong><br />
&gt;&gt; Rainer Frotscher – MR (Germany)<br />
<strong>Predictive and maintenance free tools and accessories for transformer and OLTC (or similar)</strong><br />
&gt;&gt; Stefano Vignali – MR (Italy)</p>
<p><strong>Round Table on “DGA Online monitoring, techniques and devices” with</strong><br />
&gt;&gt; Donald Skelly – Qualitrol (Ireland)<br />
&gt;&gt; Tony McGrail – Morgan shaffer – Doble  (USA)<br />
&gt;&gt; to be defined<br />
&gt;&gt; Marco Tozzi – Camlin (Ireland)<br />
Moderated by Luc Paulhiac* – EDF (France)</p>
<p><strong>Condition monitoring on asset health indices and probability of failure with lessons learned updates from the field</strong><br />
&gt;&gt; Tony McGrail – Doble (USA)</p>
<p><strong><a href="https://www.mytransfo.com/agenda/?lang=fr">Lire toutes les interventions prévues jusqu&#8217;à présent…</a></strong></p>
<p>&nbsp;</p>
<h2>Quand l&#8217;ordre du jour final sera-t-il prêt?</h2>
<p>Nous faisons de notre mieux pour enrichir l&#8217;agenda jusqu&#8217;à quelques jours avant l&#8217;événement. En réalité, la composition précise et définitive des interventions n’est pas connue, les inscriptions sont donc réduites de 50% jusqu’au 31 août.</p>
<p><strong><a href="https://www.mytransfo.com/come-partecipare/?lang=fr">Voir tarifs</a></strong></p>
<p>&nbsp;</p>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-5375-1537162264]" href="https://seamarconi.com/wp-content/uploads/2018/08/s.gazzola-80-e15338031295781.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="1000" height="667" src="https://seamarconi.com/wp-content/uploads/2018/08/s.gazzola-80-e15338031295781.jpg" class="vc_single_image-img attachment-full" alt="" title="s.gazzola-80-e1533803129578[1]" srcset="https://seamarconi.com/wp-content/uploads/2018/08/s.gazzola-80-e15338031295781.jpg 1000w, https://seamarconi.com/wp-content/uploads/2018/08/s.gazzola-80-e15338031295781-300x200.jpg 300w, https://seamarconi.com/wp-content/uploads/2018/08/s.gazzola-80-e15338031295781-768x512.jpg 768w" sizes="(max-width: 1000px) 100vw, 1000px" /></a>
		</figure>
	</div>

<p>The post <a href="https://seamarconi.com/fr/newsblog/est-disponible-le-premier-jet-de-lagenda-de-my-transfo-2018/">Est disponible le premier jet de l&#8217;agenda de My Transfo 2018</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>La Dépolarisation du Soufre Corrosif dans le désert la d’Atacama au Chili s’est conclue avec succès</title>
		<link>https://seamarconi.com/fr/newsblog/conclusa-con-successo-la-depolarizzazione-da-zolfo-corrosivo-nel-deserto-di-atacama-in-cile/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 27 Sep 2013 11:15:49 +0000</pubDate>
				<category><![CDATA[C1]]></category>
		<category><![CDATA[DBDS]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[transformateur]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107941</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/newsblog/conclusa-con-successo-la-depolarizzazione-da-zolfo-corrosivo-nel-deserto-di-atacama-in-cile/">La Dépolarisation du Soufre Corrosif dans le désert la d’Atacama au Chili s’est conclue avec succès</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Une de missions le plus “extrêmes” conduites par Sea Marconi s’est conclue avec succès: le traitement de 6 transformateurs auprès du désert d’Atacama au <strong>Chili</strong>, le lieu plus sec de la planète, à 3000 m d’altitude au-dessus du niveau de la mer, avec une amplitude thermique entre le jour et la nuit de plus de 30° C.<br />
Nos techniciens opérationnels ont été capables de s’adapter aux conditions vraiment difficiles comme, par exemple, la solitude totale, l’altitude, les conditions climatiques.</p>
<p>Pour entrer dans les détails, l’activité développée par nos techniciens a été la Dépolarisation Sélective du Soufre Corrosif (<strong>C1 – DBDS &amp; Corrosive Sulfur</strong>) sur de transformateurs d’une très grande taille, presque 120 tonnes d’huile par machine (250 MVA, 345 KV).</p>
<p>Le Client, <strong><a href="http://www.aesgener.cl/">AES Gener</a></strong> – Société multinationale américaine de l’énergie – a exprimé concrètement son appréciation pour le travail de Sea Marconi: sous peu un rapport à quatre mains sera rédigé et il sera présenté par AES Gener comme un cas de très bonne expérience dans la gestion du problème du <strong>Soufre Corrosif</strong>.<br />
La mission au Chili a mis en évidence et fait touché du doigt l’efficacité de solutions soutenables Sea Marconi pour le LCM (Life Cycle Management – Gestion du Cycle de Vie) aussi dans l’Amérique du Sud. Ce succès a déjà eu un grand retentissement en Colombie, à Panama et en Uruguay, où la Dépolarisation Chedcos par Sea Marconi est en train d’être adoptée comme réponse vraiment efficace au problème de la corrosivité des huiles isolantes.</p>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_2dd034006f7d4cca2397d513541df763"><div class="col span_1_of_2 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/09/trattamento_cile111.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/09/trattamento_cile111.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div><div class="col span_1_of_2 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/09/trattamento_cile211.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/09/trattamento_cile211.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div></div></div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/newsblog/conclusa-con-successo-la-depolarizzazione-da-zolfo-corrosivo-nel-deserto-di-atacama-in-cile/">La Dépolarisation du Soufre Corrosif dans le désert la d’Atacama au Chili s’est conclue avec succès</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Élimination de la corrosion des métaux dissous (C4) et des boues Italie 2003</title>
		<link>https://seamarconi.com/fr/portfolio_item/elimination-de-la-corrosion-des-metaux-dissous-c4-et-des-boues/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:51:53 +0000</pubDate>
				<category><![CDATA[C4]]></category>
		<category><![CDATA[Italie]]></category>
		<category><![CDATA[métaux]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4208</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-de-la-corrosion-des-metaux-dissous-c4-et-des-boues/">Élimination de la corrosion des métaux dissous (C4) et des boues &lt;strong&gt;Italie 2003&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Hydro power plant</strong></p>
<p>Nameplate data of transformer:</p>
<p>Transformer: GSU transformer<br />
Power [MVA]: <strong>30<br />
</strong>Voltage [KV]: <strong>130<br />
</strong>Oil mass [Kg]: <strong>58.000 </strong><strong><br />
</strong>Oil type: paraffinic </p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h3>Before the treatment</h3>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Cu </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>43</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>0,213</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Color</strong></td>
<td style="text-align: center;" valign="top"><strong>3</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>1,268</strong></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution Sea Marconi</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Solution: <strong>Selective Depolarization</strong> treatment (Chedcos) performed on-load (transformer fully load during the treatment)</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="500" height="375" src="https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione.jpg" class="vc_single_image-img attachment-full" alt="" title="Trattamento di depolarizzazione selettiva Chedcos e Desludging" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione.jpg 500w, https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione-300x225.jpg 300w" sizes="auto, (max-width: 500px) 100vw, 500px" /></div><figcaption class="vc_figure-caption">Selective depolarization treatment: Chedcos</figcaption>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h3>Before the treatment</h3>
</td>
<td style="text-align: center;" valign="top">
<h3>After the treatment</h3>
</td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Cu </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>43</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>1,23</strong></span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>0,213</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>0,03</strong></span></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>Color</strong></td>
<td style="text-align: center;" valign="top"><strong>3</strong></td>
<td style="text-align: center;" valign="top"><strong>1</strong></td>
</tr>
<tr>
<td style="text-align: center;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>1,268</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>0,074</strong></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="296" src="https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED.jpg" class="vc_single_image-img attachment-full" alt="" title="caso15_IFED" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED.jpg 600w, https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED-300x148.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div><figcaption class="vc_figure-caption">Fingerprint dell’olio</figcaption>
		</figure>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-de-la-corrosion-des-metaux-dissous-c4-et-des-boues/">Élimination de la corrosion des métaux dissous (C4) et des boues &lt;strong&gt;Italie 2003&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Élimination des PCB et du soufre corrosif non DBDS (C2) France 2013</title>
		<link>https://seamarconi.com/fr/portfolio_item/elimination-des-pcb-et-du-soufre-corrosif-non-dbds-c2/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:50:34 +0000</pubDate>
				<category><![CDATA[C2]]></category>
		<category><![CDATA[Décontamination des PCB]]></category>
		<category><![CDATA[France]]></category>
		<category><![CDATA[NON DBDS]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[PCB]]></category>
		<category><![CDATA[Traitement PCB]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4206</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-des-pcb-et-du-soufre-corrosif-non-dbds-c2/">Élimination des PCB et du soufre corrosif non DBDS (C2) &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-8"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Nameplate data of transformer:</p>
<p>Transformer: grid transformer<br />
Manufacturer: xxx<br />
Year: 1957<br />
Power [MVA]: <strong>50<br />
</strong>Voltage [KV]: <strong>225<br />
</strong>Oil Mass [Kg]:<strong> 38.000<br />
</strong>Oil type: blended mineral oil</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4206-3632358353]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso13_trasformatore.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="410" height="311" src="https://seamarconi.com/wp-content/uploads/2013/05/caso13_trasformatore.jpg" class="vc_single_image-img attachment-full" alt="" title="caso13_trasformatore" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso13_trasformatore.jpg 410w, https://seamarconi.com/wp-content/uploads/2013/05/caso13_trasformatore-300x228.jpg 300w" sizes="auto, (max-width: 410px) 100vw, 410px" /></a><figcaption class="vc_figure-caption">Trasformatore affetto da PCB e presenza di composti corrosivi solforati</figcaption>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Solution</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong><a title="Depolarization from corrosive sulfur" href="https://seamarconi.com/en/services/depolarisation-against-corrosive-sulphur-in-oil/">Selective depolarization</a> treatment (Chedcos)</strong> in order to remove corrosive sulfur compounds and <a title="Dehalogenation of PCBs in oil" href="https://seamarconi.com/en/services/dehalogenation-removal-of-pcbs-in-oil/"><strong>dehalogenation treatment</strong></a> (CDP Process®) in order to remove the PCBs from oil and transformer. The treatment was performerd on-site and<strong> on-load</strong> (transformer in operation and fully load during the treatment).</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h3>Before the treatments</h3>
</td>
<td style="text-align: center;" valign="top">
<h3><b>After the treatments Sea Marconi</b></h3>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>PCB* </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>81</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>20</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Total sulfur </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><strong>21,600</strong></td>
<td style="text-align: center;" valign="top"><strong>20,500</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TCS</strong> (total corrosive sulfur)<br />
as DBDS Eq.<strong> </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>140</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>&lt; 10</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>CCD</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>Corrosive</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>NOT Corrosive</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DBTP </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><strong>380</strong></td>
<td style="text-align: center;" valign="top"><b>280</b></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><strong>0,096</strong></td>
<td style="text-align: center;" valign="top"><b>&lt; 0,03</b></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong><b>IFT</b></strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>19,5</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>26</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong><b>Color</b></strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>6,9</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>3</b></span></td>
</tr>
</tbody>
</table>
<p>*The agreed guarantee was PCBs &lt; 40 [mg/Kg]</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-des-pcb-et-du-soufre-corrosif-non-dbds-c2/">Élimination des PCB et du soufre corrosif non DBDS (C2) &lt;strong&gt;France 2013&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Élimination du soufre corrosif avec DBDS (C1) Italie 2005</title>
		<link>https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-avec-dbds-2/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:44:45 +0000</pubDate>
				<category><![CDATA[C1]]></category>
		<category><![CDATA[DBDS]]></category>
		<category><![CDATA[Italie]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[transformateur]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4197</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-avec-dbds-2/">Élimination du soufre corrosif avec DBDS (C1) &lt;strong&gt;Italie 2005&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>4</strong> GSU transformer at thermal power plant</p>
<p>Nameplate data of the transformers:</p>
<p>Manufacturer: xxx<strong><br />
</strong>Year: <strong>1997<br />
</strong>Power [MVA]: <strong>192<br />
</strong>Voltage [KV]: <strong>400<br />
</strong>Oil mass [Kg]: <strong>58.000<br />
</strong>Oil type: <strong>naphthenic</strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>May 2005</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>The analysis and subsequent diagnosis performed by Sea Marconi on the equipment of the customer showed:</p>
<p>Index of corrosiveness =<strong>1</strong> (max level)<br />
ASTM b 48H= <strong>4C</strong><br />
Overall Health index: <strong>0.52</strong> (<strong>52%</strong>)</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-2014851053]" href="https://seamarconi.com/wp-content/uploads/2013/05/isabjpg.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="859" height="526" src="https://seamarconi.com/wp-content/uploads/2013/05/isabjpg.jpg" class="vc_single_image-img attachment-full" alt="" title="isabjpg" srcset="https://seamarconi.com/wp-content/uploads/2013/05/isabjpg.jpg 859w, https://seamarconi.com/wp-content/uploads/2013/05/isabjpg-300x184.jpg 300w, https://seamarconi.com/wp-content/uploads/2013/05/isabjpg-768x470.jpg 768w" sizes="auto, (max-width: 859px) 100vw, 859px" /></a>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>April 15, 2006</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Failure caused by discharges of high energy</strong></p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-3294466101]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione2.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="346" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione2.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_zolfo-corrosivo_ispezione2" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione2.jpg 600w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione2-300x173.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></a><figcaption class="vc_figure-caption">Gli avvolgimenti ad alta tensione mostrano chiaramente gli effetti del danno</figcaption>
		</figure>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>April 19, 2006</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Internal inspection and <strong>post failure analysis</strong> performed by Sea Marconi experts</p>

		</div>
	</div>
<div class="vc_row wpb_row vc_inner vc_row-fluid vc_row-o-equal-height vc_row-o-content-middle vc_row-flex"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-4100580540]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="359" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_zolfo-corrosivo_ispezione" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione.jpg 600w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_zolfo-corrosivo_ispezione-300x180.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></a><figcaption class="vc_figure-caption">Ispezione a seguito di avaria da scarica ad alta energia per zolfo corrosivo</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-850880731]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_mappa-visuale-zolfo-corrosivo.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="339" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_mappa-visuale-zolfo-corrosivo.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_mappa-visuale-zolfo-corrosivo" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_mappa-visuale-zolfo-corrosivo.jpg 600w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_mappa-visuale-zolfo-corrosivo-300x170.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></a><figcaption class="vc_figure-caption">Mappa visuale che rappresenta in forma bidimensionale i differenti livelli di corrosione sugli avvolgimenti</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-335239890]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_carte-solfuro-di-rame.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="299" height="375" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_carte-solfuro-di-rame.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_carte-solfuro-di-rame" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_carte-solfuro-di-rame.jpg 299w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_carte-solfuro-di-rame-239x300.jpg 239w" sizes="auto, (max-width: 299px) 100vw, 299px" /></a><figcaption class="vc_figure-caption">Carte isolanti sulle quali si evidenzia presenza di solfuro di rame. Il solfuro diminuisce negli strati più interni</figcaption>
		</figure>
	</div>
</div></div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>November 2006 – Solution</span></h2><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Solution: <a title="Depolarization from corrosive sulfur" href="https://seamarconi.com/en/services/depolarisation-against-corrosive-sulphur-in-oil/"><strong>Selective depolarization</strong></a> treatment<strong> </strong>(Chedcos)<strong> by Sea Marconi</strong> performed on the twins transformers.</p>
<p>he treatment guaranteed <strong>DBDS &lt; 10 mg/kg</strong> and at the same time the restoring of the other parameters according the IEC 60422 ed. 4, 2013</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-4214120557]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_depolarizzazione1.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="565" height="423" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_depolarizzazione1.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_depolarizzazione1" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_depolarizzazione1.jpg 565w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_depolarizzazione1-300x225.jpg 300w" sizes="auto, (max-width: 565px) 100vw, 565px" /></a>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-4"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-4197-413552613]" href="https://seamarconi.com/wp-content/uploads/2013/05/caso2_grafico-parametri2.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="597" height="373" src="https://seamarconi.com/wp-content/uploads/2013/05/caso2_grafico-parametri2.jpg" class="vc_single_image-img attachment-full" alt="" title="caso2_grafico-parametri2" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso2_grafico-parametri2.jpg 597w, https://seamarconi.com/wp-content/uploads/2013/05/caso2_grafico-parametri2-300x187.jpg 300w" sizes="auto, (max-width: 597px) 100vw, 597px" /></a>
		</figure>
	</div>
</div></div></div></div>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="0" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h4><strong>Before treatment</strong></h4>
</td>
<td style="text-align: center;" valign="top">
<h4><b>After treatment</b></h4>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DBDS</strong> [mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>110</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>&lt; 5</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>IFT </strong>[mN/m]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>17</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>40</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><b>0,133</b></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>&lt; 0,01</b></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top">0,0448</td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><b>0,0118</b></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/portfolio_item/elimination-du-soufre-corrosif-avec-dbds-2/">Élimination du soufre corrosif avec DBDS (C1) &lt;strong&gt;Italie 2005&lt;/strong&gt;</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</title>
		<link>https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 16 Apr 2013 08:23:17 +0000</pubDate>
				<category><![CDATA[huile]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[sous-produits de soufre]]></category>
		<category><![CDATA[Argile smectique]]></category>
		<category><![CDATA[transformateur]]></category>
		<category><![CDATA[traitement de l'huile]]></category>
		<category><![CDATA[soufre corrosif]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107909</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/">Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p class="qtranxs-available-languages-message qtranxs-available-languages-message-fr">La traduction en français est en cours. Si vous visitez le site dans quelques jours, il sera intégralement en français. En attendant, vous pouvez visualiser le site en <a href="https://seamarconi.com/it/tag/olio-isolante/" class="qtranxs-available-language-link qtranxs-available-language-link-it" title="Italiano">Italiano</a> ou en <a href="https://seamarconi.com/en/tag/insulating-oil/" class="qtranxs-available-language-link qtranxs-available-language-link-en" title="English">English</a>. Si vous visitez le site dans quelques jours, il sera intégralement en français. En attendant, vous pouvez visualiser le site en italien ou en anglais.</p><div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Analyse comparative entre les différentes traitements disponibles pour la gestion du cycle de vie des huiles et transformateurs</span></h3>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Télécharger le PDF: <a title="Download Trattamenti Sea Marconi vs Terre follari ITA" href="https://seamarconi.com/wp-content/uploads/2017/09/Scheda-trattamenti-integrati-e-DMU-vs-terre-follari_ITA.pdf" target="_blank" rel="noopener noreferrer"><b>Trattamenti Sea Marconi vs Terre follari ITA</b></a> (379.5 KiB)</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table style="width: 100%;" border="1" cellspacing="0" cellpadding="2">
<tbody>
<tr>
<td>
<div align="center"><b>FACTEURS CLE</b></div>
</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"><strong><b>DMU &amp; Traitements intégrés* Brevets Sea Marconi</b><br />
</strong></span></span></div>
</td>
<td>
<div align="center">Traitement par terres à foulons classique</div>
</td>
<td>
<div align="center">Traitement par terres à foulons avec régénération à T° &gt; 600-700 °C</div>
</td>
</tr>
<tr>
<td><b>Récupération : propriétés physiques :</b>KV, Gas dissous, H<sub>2</sub>O</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #339966;">Oui</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Récupération : propriétés chimiques : </b>Acidité, Facteur de dissipation, Tension interfaciale</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #339966;">Oui</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Décontamination : DBDS &amp; Soufres corrosifs  (cas C1 à C4)</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><span style="font-family: Verdana;"><span style="font-size: small;"> <strong><span style="color: #ff0000;">Non</span></strong></span></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Decontamination: Métaux en solution</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Déhalogenation : PCB</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Classification: BAT/BEP </b>– Meilleure technologie disponible , Best Practices (PCBs/POPs)</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Self-cleaning de l’unité : DBDS, PCBs/POPs</b></td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #339966;">Oui</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana; font-size: small;"> <span style="color: #ff0000;">Non</span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Contamination croisée par DBDS,  PCBs/POPs</b></td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <b>Sécurité</b></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Corrosion par sous-produits de dégradation du soufre (SDBP)</b><b></b>comme  H<sub>2</sub>S, Mercaptans, etc. causée par température élevée (&gt; 370 °C – typiques 600-700 °C)</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
<tr>
<td><b>Risques de Formation de Dioxines (PCDDs, PCDFs)</b><b> </b>lors de l’étape de regeneration à Haute T° dans le cas des huiles contaminées par PCB PCT PCBT</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><span style="color: #339966; font-size: small;"><strong><span style="font-family: Verdana;"> <span style="font-family: Verdana;"><b>Sécurité</b></span></span></strong></span></div>
</td>
<td>
<div align="center"><strong><span style="font-family: Verdana;"><span style="font-size: small;"> <span style="color: #ff0000;">Danger</span></span></span></strong></div>
</td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>*<strong>CDP Process<sup>®</sup></strong> for PCBs/POPs chemical dehalogenation; <strong>CHEDCOS</strong> for DBDS &amp; Corrosive Sulfur Selective Depolarization</p>

		</div>
	</div>
<h2 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Cas «C3 – SDBP** et soufre corrosif»</span></h2><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>URUGUAY 2010</span></h3></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-3"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="379" height="304" src="https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco.jpg" class="vc_single_image-img attachment-full" alt="Segni di arco elettrico sui contatti del selettore" title="Segni di arco elettrico sui contatti del selettore" srcset="https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco.jpg 379w, https://seamarconi.com/wp-content/uploads/2017/09/caso14_segni-di-arco-300x241.jpg 300w" sizes="auto, (max-width: 379px) 100vw, 379px" /></div><figcaption class="vc_figure-caption">Segni di arco elettrico sui contatti del selettore</figcaption>
		</figure>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-9"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><i>Le diagnostic post-avarie sur le Transformer a montré des <b>signes d’arcs électriques</b> sur les contacts sélecteur de prises. L’avarie a été <b>causée par la formation de sulfures de Cuivre/Ag</b>,  tels que  CuS, Cu<sub>2</sub>S, Ag<sub>2</sub>S, etc. En effet, «</i><i>à relativement haute température, les molécules d’huile contenant du soufre peuvent se décomposer et réagissent avec la surface métallique pour former des sulfures métalliques</i>”  (IEC 60422 éd. 4 – 2013 Art 5,17). Ce mécanisme à eu lieu lors du processus de régénération de l’huile à l’étape de réactivation de la colonne de terres par la combustion non contrôlée (&gt; 370 ° C). Les composés sulfurés présents naturellement dans l’huile, ainsi que les additifs (Dibenzothiophene – DBTP, etc) (DBDS, etc), sont alors décomposés en **<b>sous-produits de dégradation du soufre</b>. Autres cas typiques : National Grid Ref (UK), ABB (Suède), 2010 Conférence Doble (USA)</p>

		</div>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h3 class="boc_heading  center  "  style="margin-bottom: 20px;margin-top: 0px;color: #333;"><span>Soluzioni sostenibili Sea Marconi – Valore aggiunto per i clienti, detentori e partners:</span></h3>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<ul>
<li><b>45 ans d’innovation</b> pour la gestion du cycle de vie des huiles et des transformateurs.</li>
<li>Des solutions basées sur l’approche globale et intégrée, les case history, l’état de l’art, les normes <b>CEI</b>, les lignes directrices du <b>CIGRE</b>, la Convention de Stockholm sur les POP (polluants organiques persistants).</li>
<li>Solutions pour la prévention et / ou atténuation des pertes et des risques pour les actifs, les travailleurs, la santé publique et l’environnement.</li>
<li>Focus sur des problématiques prioritaires  pour les équipements électriques en huiles isolantes. <b>Diagnostic</b> (&gt; 150.000 cas) et des traitements intégrés (&gt; 700 transformateurs de puissance – 2012 par <b>Unité mobile</b>, garantissent une expertise indépendante, la fiabilité, le contrôle de la qualité (ISO 9001-2008, ACCREDIA ISO 17025), la traçabilité, les avantages économiques et environnementaux.</li>
</ul>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/newsblog/trattamenti-dellolio-isolante-soluzioni-sea-marconi-vs-trattamenti-con-terre-follari/">Traitements des huiles diélectriques: “Solutions Sea Marconi” vs “Traitements sur terres à foulons”</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Très suivi le séminaire organisé en Espagne</title>
		<link>https://seamarconi.com/fr/newsblog/seguitissimo-anche-il-workshop-su-trasformatore-e-olio-organizzato-in-spagna/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Wed, 16 Nov 2011 11:54:51 +0000</pubDate>
				<category><![CDATA[mise à jour technique]]></category>
		<category><![CDATA[huile]]></category>
		<category><![CDATA[huile isolante]]></category>
		<category><![CDATA[transformateur]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107736</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/fr/newsblog/seguitissimo-anche-il-workshop-su-trasformatore-e-olio-organizzato-in-spagna/">Très suivi le séminaire organisé en Espagne</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>10 novembre 2011, Barcelone, Sea Marconi organisa le «<strong>Oil &amp; Transfo Workshop</strong>» séminaire de perfectionnement technique dédié aux opérateurs du secteur de la gestion d’appareillages électriques contenant de fluides isolants.</p>
<p>Après le résultat extraordinairement positif de Arezzo et de Vérone, Sea Marconi répète le format de ses évents à Barcelone et, aussi dans cet endroit, on retrouve une ultérieure salle bondée de spectateurs et une attention très, très élevée jusqu’à la fin de la journée.</p>
<p><strong><a href="http://www.bioenpro.com/modules.php?name=Max_iFrame&amp;op=viewpage&amp;id=21">L’évent de Barcelone</a></strong> a été un grand succès avant tout pour l’élevée participation, 56 participants provenant de toute l’Espagne et du Portugal, et pour l’échange de questions et réponses alimenté par un parterre vraiment attentif et compétent.</p>
<p>En outre de M. Vander Tumiatti, membre associé gérant et fondateur de Sea Marconi, le responsable du Laboratoire Sea Marconi M. Riccardo MAINA, M. Riccardo ACTIS, Direction de services techniques, M. Pedro MENDEZ du service commercial espagnol ont participé comme intervenants avec l’invité de cette journée, que je remercie beaucoup pour sa participation, Mme. Inmaculada GUERRERO (Direction Développement et Maintenance de la Société ENDESA Distribución Eléctrica).</p>
<p>Le cycle des évents organisé par Sea Marconi pour l’année 2011 va terminer ici. Sûrement, en considérant les plusieurs demandes de participation déjà parvenues, les séminaires «Oil &amp; Transfo Workshop» continueront aussi pendant le 2012 pour, à la fin de l’année, être couronnés par la sixième édition du Congrès «<strong><a href="http://www.bioenpro.com/myt10/fra/index.php">My Transfo Meeting</a></strong>».</p>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_c5ffe4a2de345105d71777d264f65746"><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona1.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona1.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona2.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona3.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona3.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div><div class="col span_1_of_4 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona4.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/08/workshop_barcelona4.jpg" alt="" />
								<div class='img_overlay'><span class='hover_icon icon_zoom'></span></div>
							</a>	</div></div></div></div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/fr/newsblog/seguitissimo-anche-il-workshop-su-trasformatore-e-olio-organizzato-in-spagna/">Très suivi le séminaire organisé en Espagne</a> appeared first on <a href="https://seamarconi.com/fr">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
