	<title>Acqua nel trasformatore Archives - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/it/portfolio_category/acqua-nel-trasformatore-2/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/portfolio_category/acqua-nel-trasformatore-2/</link>
	<description>Soluzioni sostenibili per la gestione del ciclo di vita (LCM) di trasformatori con oli isolanti</description>
	<lastBuildDate>Fri, 19 Apr 2024 08:24:30 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>Spagna 2020/21 Disidratazione dell’olio e dell’isolamento cellulosico dei trasformatori</title>
		<link>https://seamarconi.com/it/portfolio_item/spagna-202021-disidratazione-dellolio-e-dellisolamento-cellulosico-dei-trasformatori/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Tue, 20 Apr 2021 10:18:42 +0000</pubDate>
				<category><![CDATA[acqua in olio]]></category>
		<category><![CDATA[deumidificazione]]></category>
		<category><![CDATA[trattamento integrato]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=portfolio&#038;p=114415</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/it/portfolio_item/spagna-202021-disidratazione-dellolio-e-dellisolamento-cellulosico-dei-trasformatori/">&lt;strong&gt;Spagna 2020/21&lt;/strong&gt; Disidratazione dell’olio e dell’isolamento cellulosico dei trasformatori</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>3 trasformatori monofase installati in centrale produzione termoelettrica nel sud della Spagna</p>
<p>&nbsp;</p>
<p>Caratteristiche tecniche del trasformatore:</p>
<p>Costruttore.: xxx<br />
Anno: <strong>1977</strong><br />
Potenza [MVA]: <strong>216</strong><br />
Tensione [KV]: <strong>220/22</strong><br />
Massa di olio [Kg]: <strong>15.650</strong> cad.</p>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_right wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="300" height="400" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador1" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1.jpg 300w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador1-225x300.jpg 225w" sizes="(max-width: 300px) 100vw, 300px" /></div>
		</figure>
	</div>
</div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h1 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problema</span></h1>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Le analisi periodiche dell’olio evidenziavano una condizione di idratazione dell’isolamento cellulosico. Il contenuto stimato di acqua negli isolanti solidi compresa tra 3 e 4% in peso, condizione tipica per apparecchiature con &gt; 30 anni di servizio.</p>

		</div>
	</div>
<h1 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Soluzione</span></h1><div class="vc_row wpb_row vc_inner vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi ha eseguito la seguente attività:</p>
<p><a href="https://seamarconi.com/it/servizi/disidratazione-o-deumidificazione-trasformatore-carte/"><strong>disidratazione dell’olio e dell’isolamento cellulosico mediante circolazione di olio caldo e trattamento sotto vuoto dell’olio</strong></a>.</p>
<p>Il processo è stato eseguito con trasformatore in servizio.</p>
<p><strong>Dettaglio delle fasi dell’intervento</strong></p>
<ul>
<li>Collegamento idraulico delle apparecchiature di trattamento con trasformatore fuori servizio temporaneo.</li>
<li>Esecuzione del processo di disidratazione con trasformatore in servizio</li>
<li>Scollegamento delle apparecchiature con trasformatore in servizio.</li>
</ul>
<p><strong>Criteri per l&#8217;arresto del trattamento</strong></p>
<ul>
<li>Acqua in olio &lt; 10 mg/kg a t&gt; 40°C</li>
<li>Tensione discarica &gt; 70 kV</li>
<li>Acqua estratta &lt; 250 ml/24h</li>
</ul>

		</div>
	</div>
</div></div></div><div class="wpb_column vc_column_container vc_col-sm-6"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="600" height="338" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador2" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2.jpg 600w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador2-300x169.jpg 300w" sizes="(max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
<div class="boc_spacing " style="height: 40px"></div>
	<div  class="wpb_single_image wpb_content_element vc_align_left wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="600" height="338" src="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3.jpg" class="vc_single_image-img attachment-full" alt="" title="Secado_de_papeles_transformador3" srcset="https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3.jpg 600w, https://seamarconi.com/wp-content/uploads/2021/04/Secado_de_papeles_transformador3-300x169.jpg 300w" sizes="(max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
</div></div></div></div></div></div></div></div><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Dettagli del trattamento</strong></p>
<p>Il processo è stato eseguito con trasformatore in servizio.<br />
La temperatura dell’olio nel cassone (top oil)  è stata mantenuta costantemente superiore a 70°C mediante l’impiego di una apparecchiatura ausiliaria di riscaldamento.<br />
Simultaneamente l’olio è stato ricircolato attraverso una apparecchiatura di disidratazione sotto vuoto. Complessivamente <strong>sono stati estratti circa 15 litri di acqua da ogni apparecchio</strong>.</p>
<p><i class="fa fa-clock-o fa-2x "></i><strong>Durata</strong> complessiva dell’intervento: 6 settimane (2 per ogni trasformatore)</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/it/portfolio_item/spagna-202021-disidratazione-dellolio-e-dellisolamento-cellulosico-dei-trasformatori/">&lt;strong&gt;Spagna 2020/21&lt;/strong&gt; Disidratazione dell’olio e dell’isolamento cellulosico dei trasformatori</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Francia 2012 Disidratazione e riempimento trasformatore</title>
		<link>https://seamarconi.com/it/portfolio_item/francia-2012-disidratazione-e-riempimento-trasformatore/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 12 Jun 2015 14:55:26 +0000</pubDate>
				<category><![CDATA[Riempimento]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=17220</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/it/portfolio_item/francia-2012-disidratazione-e-riempimento-trasformatore/">&lt;strong&gt;Francia 2012&lt;/strong&gt; Disidratazione e riempimento trasformatore</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Azienda leader internazionale nel settore dell’energia e delle infrastrutture</p>
<p>Caratteristiche tecniche del trasformatore:</p>
<p>Costruttore.: xxx<strong><br />
</strong>Anno: <strong>2012 (nuovo)<br />
</strong>Potenza [MVA]: <strong>80<br />
</strong>Tensione [KV]: <strong>227/21/21</strong><br />
Massa di olio [Kg]: <strong>26.700</strong></p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="400" src="https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers.jpg" class="vc_single_image-img attachment-full" alt="" title="riempimento_villers" srcset="https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers.jpg 600w, https://seamarconi.com/wp-content/uploads/2015/06/riempimento_villers-300x200.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div>
		</figure>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Problema</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>A seguito della richiesta iniziale di <strong>riempire</strong> il trasformatore nuovo, i tecnici Sea Marconi in campo si accorgono della presenza di <strong>acqua libera</strong> all’interno del trasformatore.</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element bq_yellow" >
		<div class="wpb_wrapper">
			<blockquote><p>
La causa risiede nel non aver sigillato correttamente il trasformatore prima del suo trasporto.
</p></blockquote>

		</div>
	</div>
<div class="grid_holder mfp_gallery  small_spacing" id="img_gallery_8bf300d142a1c2f612b5f5cd81f7f38e"><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione2.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione2-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione1.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2017/03/acqua-in-sospensione1-600x380.jpg" alt="" />
								
							</a>	</div></div><div class="col span_1_of_3 info_item isotope_element">
							<div class="pic  img_hover_effect1">			
							<a href="https://seamarconi.com/wp-content/uploads/2015/06/acqua-libera_villers3.jpg" class="mfp_popup_gal" title="">
								<img decoding="async" src="https://seamarconi.com/wp-content/uploads/2015/06/acqua-libera_villers3-600x380.jpg" alt="" />
								
							</a>	</div></div></div><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Soluzione</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Sea Marconi ha eseguito un’attività piuttosto complessa suddivisa in tre fasi operative:</p>
<ol>
<li><strong><a title="Disidratazione o deumidificazione trasformatore (carte)" href="https://seamarconi.com/servizi/disidratazione-o-deumidificazione-trasformatore-carte/">Disidratazione delle carte</a> mediante la tecnica di disidratazione diretta “olio caldo + vuoto”</strong><br />
Questa fase prevede l’esecuzione del vuoto alla cassa del trasformatore, il riempimento con olio caldo fino a coprire gli avvolgimenti, lo svuotamento rapido del trasformatore, la ripetizione di queste operazioni fino al raggiungimento di valori stabiliti (acqua &lt; 10 mg/Kg; rigidità dielettrica &gt; 70 KV; quantità di acqua estratta &lt; 0,25 l/24 ore).</li>
<li><strong>Riempimento e trattamento</strong><br />
Questa fase prevede l’esecuzione del vuoto alla cassa del trasformatore, il riempimento con olio ed il successivo trattamento fisico ed esecuzione degli sfiati</li>
</ol>
<p>L’attività è durata complessivamente poco più di <strong>due settimane</strong>, durante le quali sono stati estratti <strong>2,85 l di acqua</strong> dal sistema olio/trasformatore.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img loading="lazy" decoding="async" width="600" height="208" src="https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta.jpg" class="vc_single_image-img attachment-full" alt="" title="acqua-estratta" srcset="https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta.jpg 600w, https://seamarconi.com/wp-content/uploads/2015/06/acqua-estratta-300x104.jpg 300w" sizes="auto, (max-width: 600px) 100vw, 600px" /></div><figcaption class="vc_figure-caption">L’acqua estratta diminuisce a seguito del trattamento descritto al punto 1<p>The post <a href="https://seamarconi.com/it/portfolio_item/francia-2012-disidratazione-e-riempimento-trasformatore/">&lt;strong&gt;Francia 2012&lt;/strong&gt; Disidratazione e riempimento trasformatore</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Francia 2008 Disidratazione delle carte e del trasformatore</title>
		<link>https://seamarconi.com/it/portfolio_item/francia-2008-disidratazione-delle-carte-e-del-trasformatore/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:52:22 +0000</pubDate>
				<category><![CDATA[acqua in olio]]></category>
		<category><![CDATA[deumidificazione]]></category>
		<category><![CDATA[Francia]]></category>
		<category><![CDATA[trattamento olio]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4209</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/it/portfolio_item/francia-2008-disidratazione-delle-carte-e-del-trasformatore/">&lt;strong&gt;Francia 2008&lt;/strong&gt; Disidratazione delle carte e del trasformatore</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><b>Centrale idroelettrica </b></p>
<p><b></b>Caratteristiche tecniche dei trasformatori:</p>
<p>Tipo trasformatore: trasformatore di potenza<br />
Anno: <strong>1948</strong><br />
Potenza [MVA]: <strong>33<br />
</strong>Tensione [KV]: <strong>225<br />
</strong>Massa di olio [Kg]: <strong>74.000 </strong></p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Soluzione Sea Marconi</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Soluzione: trattamento di <strong><a title="Disidratazione o deumidificazione trasformatore (carte)" href="https://seamarconi.com/servizi/disidratazione-o-deumidificazione-trasformatore-carte/">deumidificazione indiretta</a> in modalità on-load</strong> (trasformatore sotto tensione e sotto carico durante tutta la durata del trattamento)</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h4><strong>Prima del trattamento</strong></h4>
</td>
<td style="text-align: center;" valign="top">
<h4><strong>Dopo il trattamento</strong></h4>
</td>
<td style="text-align: center;" valign="top">
<h4><strong>Dopo 6 mesi</strong></h4>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><b>Temperatura dell’olio </b>[°C]</td>
<td style="text-align: center;" valign="top"><strong>15</strong></td>
<td style="text-align: center;" valign="top"><strong>63</strong></td>
<td style="text-align: center;" valign="top"><strong>35</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><b>Acqua disciolta </b>[mg/Kg] IEC 60814</td>
<td style="text-align: center;" valign="top"><b>28</b></td>
<td style="text-align: center;" valign="top"><strong>8</strong></td>
<td style="text-align: center;" valign="top"><strong>14</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Percentuale di saturazione</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #dc143c;"><b>62%</b></span></td>
<td style="text-align: center;" valign="top"><strong>3%</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #339966;"><strong>13,94%</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Acqua nelle carte usando le curve di equilibrio</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #dc143c;"><strong>&gt; 10%</strong></span></td>
<td style="text-align: center;" valign="top"><strong>(*)</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #339966;"><strong>3,9%</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Condizioni di isolamento </strong>IEC 60422</td>
<td style="text-align: center;" valign="top"><span style="color: #dc143c;"><strong>Estremamente umido</strong></span></td>
<td style="text-align: center;" valign="top"><strong>(*)</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #339966;"><strong>Moderatam. umido</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Tensione di scarica </strong>[KV] IEC 60156</td>
<td style="text-align: center;" valign="top"><strong>39,8</strong></td>
<td style="text-align: center;" valign="top"><strong>&gt; 75</strong></td>
<td style="text-align: center;" valign="top"><strong>&gt; 75</strong></td>
</tr>
</tbody>
</table>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/it/portfolio_item/francia-2008-disidratazione-delle-carte-e-del-trasformatore/">&lt;strong&gt;Francia 2008&lt;/strong&gt; Disidratazione delle carte e del trasformatore</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>