<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>metalli Archives - Sea Marconi</title>
	<atom:link href="https://seamarconi.com/it/tag/metalli/feed/" rel="self" type="application/rss+xml" />
	<link>https://seamarconi.com/it/tag/metalli/</link>
	<description>Soluzioni sostenibili per la gestione del ciclo di vita (LCM) di trasformatori con oli isolanti</description>
	<lastBuildDate>Fri, 06 Mar 2020 07:35:53 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>Italia 2003 Rimozione corrosione da metalli disciolti (C4) e sludge</title>
		<link>https://seamarconi.com/it/portfolio_item/italia-2003-rimozione-corrosione-da-metalli-disciolti-c4-e-sludge/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 31 May 2013 14:51:53 +0000</pubDate>
				<category><![CDATA[C4]]></category>
		<category><![CDATA[Italia]]></category>
		<category><![CDATA[metalli]]></category>
		<category><![CDATA[olio isolante]]></category>
		<category><![CDATA[trattamento olio]]></category>
		<category><![CDATA[zolfo corrosivo]]></category>
		<guid isPermaLink="false">http://www.bioenpro.com/wordpress01/?post_type=portfolio&#038;p=4208</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/it/portfolio_item/italia-2003-rimozione-corrosione-da-metalli-disciolti-c4-e-sludge/">&lt;strong&gt;Italia 2003&lt;/strong&gt; Rimozione corrosione da metalli disciolti (C4) e sludge</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><p style="text-align: center;"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper"><h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Scenario</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p><strong>Centrale idroelettrica italiana</strong></p>
<p>Caratteristiche tecniche dei trasformatori:</p>
<p>Tipo trasformatore: elevatore<br />
Potenza [MVA]: <strong>30<br />
</strong>Tensione [KV]: <strong>130<br />
</strong>Massa di olio [Kg]: <strong>58.000 </strong><strong><br />
</strong>Tipo olio: olio paraffinico</p>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h3>Prima del trattamento</h3>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Cu </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>43</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>0,213</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Color</strong></td>
<td style="text-align: center;" valign="top"><strong>3</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>1,268</strong></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>L’elevata presenza rame nell’olio contribuisce ad accelerare il degrado dell’olio stesso, con la formazione di composti insolubili (sludge) che si depositano sul fondo della cassa e negli interstizi del trasformatore. Questo influenza la corretta circolazione dell’olio generando un aumento delle temperature locali ed un aumento delle probabilità di guasto.</p>

		</div>
	</div>
<h2 class="boc_heading  al_left  "  style="margin-bottom: 20px;margin-top: 0px;color: #333333;font-size: 22px;"><span>Soluzione Sea Marconi</span></h2>
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Soluzione: trattamento di <strong>depolarizzazione selettiva by </strong>Sea Marconi in modalità on-load (trasformatore sotto tensione e sotto carico durante tutta la durata del trattamento) + trattamento di Desludging.</p>
<p>La rimozione dei sottoprodotti di ossidazione insolubili (<strong>sludge</strong>) è stata testimoniata dalla diminuzione della temperatura media del trasformatore di ben 5 °C. Questo è dovuto al miglioramento della dissipazione termica della macchina che, prima dell’intervento, soffriva appunto di interstizi e radiatori ostruiti dallo sludge.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img fetchpriority="high" decoding="async" width="500" height="375" src="https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione.jpg" class="vc_single_image-img attachment-full" alt="" title="Trattamento di depolarizzazione selettiva Chedcos e Desludging" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione.jpg 500w, https://seamarconi.com/wp-content/uploads/2013/05/caso15_C4_depolarizzazione-300x225.jpg 300w" sizes="(max-width: 500px) 100vw, 500px" /></div><figcaption class="vc_figure-caption">Trattamento di depolarizzazione selettiva Chedcos e Desludging</figcaption>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<table border="1" width="100%" cellspacing="1" cellpadding="3">
<tbody>
<tr>
<td style="text-align: center;" valign="top"></td>
<td style="text-align: center;" valign="top">
<h3>Prima del trattamento</h3>
</td>
<td style="text-align: center;" valign="top">
<h3>Dopo il trattamento</h3>
</td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Cu </strong>[mg/Kg]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>43</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>1,23</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>TAN </strong>[mg KOH/g]</td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>0,213</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>0,03</strong></span></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>Color</strong></td>
<td style="text-align: center;" valign="top"><strong>3</strong></td>
<td style="text-align: center;" valign="top"><strong>1</strong></td>
</tr>
<tr>
<td style="text-align: left;" valign="top"><strong>DF</strong></td>
<td style="text-align: center;" valign="top"><span style="color: #ff0000;"><strong>1,268</strong></span></td>
<td style="text-align: center;" valign="top"><span style="color: #008000;"><strong>0,074</strong></span></td>
</tr>
</tbody>
</table>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<div class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="600" height="296" src="https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED.jpg" class="vc_single_image-img attachment-full" alt="" title="caso15_IFED" srcset="https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED.jpg 600w, https://seamarconi.com/wp-content/uploads/2013/05/caso15_IFED-300x148.jpg 300w" sizes="(max-width: 600px) 100vw, 600px" /></div><figcaption class="vc_figure-caption">Fingerprint dell’olio</figcaption>
		</figure>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/it/portfolio_item/italia-2003-rimozione-corrosione-da-metalli-disciolti-c4-e-sludge/">&lt;strong&gt;Italia 2003&lt;/strong&gt; Rimozione corrosione da metalli disciolti (C4) e sludge</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Sea Marconi anticipa i sorprendenti risultati del progetto di ricerca internazionale sui meccanismi di contaminazione da metalli</title>
		<link>https://seamarconi.com/it/newsblog/sea-marconi-anticipa-i-sorprendenti-risultati-del-progetto-di-ricerca-internazionale-sui-meccanismi-di-contaminazione-da-metalli/</link>
		
		<dc:creator><![CDATA[seamarconi]]></dc:creator>
		<pubDate>Fri, 29 Apr 2011 08:56:53 +0000</pubDate>
				<category><![CDATA[liquidi isolanti]]></category>
		<category><![CDATA[metalli]]></category>
		<category><![CDATA[Università Torino]]></category>
		<guid isPermaLink="false">https://seamarconi.com/it/?post_type=newsblog&#038;p=107685</guid>

					<description><![CDATA[<p>The post <a href="https://seamarconi.com/it/newsblog/sea-marconi-anticipa-i-sorprendenti-risultati-del-progetto-di-ricerca-internazionale-sui-meccanismi-di-contaminazione-da-metalli/">Sea Marconi anticipa i sorprendenti risultati del progetto di ricerca internazionale sui meccanismi di contaminazione da metalli</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wpb-content-wrapper"><div class="vc_row wpb_row vc_row-fluid"><div class="wpb_column vc_column_container vc_col-sm-12"><div class="vc_column-inner"><div class="wpb_wrapper">
	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Come già anticipato in un <strong><a title="Sea Marconi pioniera nello studio della corrosione correlata a composti solforati e NON" href="https://seamarconi.com/it/newsblog/sea-marconi-pioniera-nello-studio-della-corrosione-correlata-a-composti-solforati-e-non/" target="_blank" rel="noopener noreferrer">articolo del giugno 2010 pubblicato su questo stesso sito web</a></strong>, Sea Marconi, in collaborazione con l’Università di Torino<sup>1</sup> (Dip. Chimica analitica), quella del Missouri (“Rolla”)<sup>2</sup> e l’istituto di ricerca serbo “NIKOLA TESLA”<sup>3</sup>, è impegnata in un progetto di ricerca promosso dal Ministero dello Sviluppo Economico per favorire l’integrazione fra Università e imprese a livello internazionale.</p>
<p>Gli studi, iniziati il 16 novembre 2009 sono alle battute conclusive, il termine dei lavori è previsto per il 16 maggio 2011.</p>
<p>Il progetto “Project n° 31. Life Cycle Assessment study of metal contaminated large power electrical apparata” ha l’obiettivo di <strong>approfondire il fenomeno della formazione e presenza di contaminanti metallici nei liquidi isolanti</strong> utilizzati in apparecchiature elettriche di grande potenza (trasformatori, reattori, raddrizzatori) impiegate nelle reti di generazione, trasmissione, distribuzione ed utilizzo dell’energia elettrica. Tale problematica, peraltro già oggetto di indagine da parte dei gruppi di normazione di settore (IEC, Cigre, ASTM, Doble, ecc.), può causare il degrado degli oli e delle apparecchiature con conseguenze anche catastrofiche. L’impatto economico su scala internazionale di tali guasti, e delle relative interruzioni di erogazione di energia elettrica (black-out), è dell’ordine dei miliardi di Euro.</p>

		</div>
	</div>

	<div  class="wpb_single_image wpb_content_element vc_align_center wpb_content_element">
		
		<figure class="wpb_wrapper vc_figure">
			<a class="" data-lightbox="lightbox[rel-107685-4258300158]" href="https://seamarconi.com/wp-content/uploads/2017/08/trasformatore_in_fiamme1.jpg" target="_self" class="vc_single_image-wrapper   vc_box_border_grey"><img decoding="async" width="400" height="266" src="https://seamarconi.com/wp-content/uploads/2017/08/trasformatore_in_fiamme1.jpg" class="vc_single_image-img attachment-full" alt="" title="trasformatore_in_fiamme1" srcset="https://seamarconi.com/wp-content/uploads/2017/08/trasformatore_in_fiamme1.jpg 400w, https://seamarconi.com/wp-content/uploads/2017/08/trasformatore_in_fiamme1-300x200.jpg 300w" sizes="(max-width: 400px) 100vw, 400px" /></a>
		</figure>
	</div>

	<div class="wpb_text_column wpb_content_element" >
		<div class="wpb_wrapper">
			<p>Ad oltre cinque anni dalla scoperta da parte di Sea Marconi e Terna del DBDS (dibenzildisolfuro), composto solforato principale responsabile dei guasti da zolfo corrosivo, è emerso che esistono oli corrosivi pur in assenza di tale sostanza. Ciò implica l’importanza della <strong>ricerca di altre sostanze solforate potenzialmente corrosive nell’olio</strong> e della valutazione dei loro effetti in presenza di rame e carta isolante.</p>
<p>Per ciò che concerne i primi risultati della ricerca, si è evidenziata innanzitutto la rilevante azione corrosiva di composti solforati, quali i solfossidi, il cui ruolo nella formazione di solfuro di rame (CuS) sino ad ora è stato considerato secondario. Si è osservato inoltre che anche <strong>oli considerati non corrosivi mostrano capacità di trasferire importanti quantitativi di rame sulla cellulosa</strong>, infine, attraverso l’esame di campioni reali, si è potuto dedurre che le perdite dielettriche degli oli sono influenzate principalmente dalla frazione di rame solubile piuttosto che da quella particellare.</p>
<p>Questo progetto vede Sea Marconi in prima linea con l’obiettivo di approfondire, in modo pionieristico, dinamiche ancora non chiare sullo scenario internazionale al fine di individuare soluzioni per il prolungamento del ciclo di vita delle apparecchiature elettriche nel rispetto e tutela dell’ambiente.</p>
<p><sup>1</sup>Prof. Corrado Sarzanini</p>
<p>Università di Torino – Dipartimento di Chimica Analitica, via P. Giuria, 5 – 10125 TORINO (ITALIA)</p>
<p><sup>2</sup>Prof. Shubhen Kapila</p>
<p>Center for Environmental Science and Technology Missouri University of Science and Technology (A Campus of the University of Missouri)</p>
<p>Rolla, MO 65409 (US)</p>
<p><sup>3</sup>Dr. Jelena Lukic,<br />
Elektrotehni?ki institut, “NIKOLA TESLA”, Koste Glavini?a 8a Srbija, 11000 Beograd</p>

		</div>
	</div>
</div></div></div></div>
</div><p>The post <a href="https://seamarconi.com/it/newsblog/sea-marconi-anticipa-i-sorprendenti-risultati-del-progetto-di-ricerca-internazionale-sui-meccanismi-di-contaminazione-da-metalli/">Sea Marconi anticipa i sorprendenti risultati del progetto di ricerca internazionale sui meccanismi di contaminazione da metalli</a> appeared first on <a href="https://seamarconi.com/it">Sea Marconi</a>.</p>