Tag: olio isolante

29
Jan
2026

My Transfo on the Road chega a Lyon: um novo capítulo local para a partilha de conhecimento técnico

  My Transfo on the Road is the local extension of the international My Transfo conference, promoted and organised by Sea Marconi since 2002. After more than twenty years of international dialogue and technical exchange, the My Transfo experience is now moving closer to local markets with a focused, one-day professional format. The first stop of this new initiative will

Leia mais

30
Set
2022

Treatment Technologies for Transformers’ Corrosive Sulphur – A great saudi workshop by GCC Lab and Sea Marconi

We are very honored to have participated in the workshop “Treatment Technologies for Transformers’ Corrosive Sulphur” organized by our saudi partner GCC Lab in Damman (Saudi Arabia) the 26 and 27 Sept. 2022.  The event was attended by 50 engineers/technicians from different clients of GCC Lab and was focused on Asset Integrity Management. Sea Marconi attended the event with 4 very high profile speakers: Cristina Tumiatti (Global Business Development Director),

Leia mais

9
Ago
2018

The very first draft of the agenda is available

The very first draft of the event agenda is available, from which it is possible to have an idea of the topics that will be discussed at the next My Transfo 2018: Solid and liquid insulating materials for high temperature, applications and case histories >> Richard Marek – Dupont (USA) Characterization of different cellulose types using dielectric frequency response (FDS) >> Britta

Leia mais

Removal of corrosion from dissolved metals (C4) and sludge Italy 2003

Scenario Hydro power plant Nameplate data of transformer: Transformer: GSU transformer Power [MVA]: 30 Voltage [KV]: 130 Oil mass [Kg]: 58.000 Oil type: paraffinic Before the treatment Cu [mg/Kg] 43 TAN [mg KOH/g] 0,213 Color 3 DF 1,268 Solution Sea Marconi Solution: Selective Depolarization treatment (Chedcos) performed on-load (transformer fully load during the treatment) Selective depolarization treatment: Chedcos Before the treatment After the
Leia mais

Removal of PCBs and non-DBDS corrosive sulfur (C2) France 2013

Scenario Nameplate data of transformer: Transformer: grid transformer Manufact: xxx Year: 1957 Power [MVA]: 50 Voltage [KV]: 225 Oil Mass [Kg]: 38.000 Oil type: blended mineral oil Trasformatore affetto da PCB e presenza di composti corrosivi solforati Solution Selective depolarization treatment (Chedcos) in order to remove corrosive sulfur compounds and dehalogenation treatment (CDP Process®) in order to remove the PCBs from oil and transformer. The treatment was
Leia mais

Remoção de enxofre corrosivo com DBDS (C1) – Itália 2005

Scenario 4 GSU transformer at thermal power plant Nameplate data of the transformers: Manufact: xxx Year: 1997 Power [MVA]: 192 Voltage [KV]: 400 Oil mass [Kg]: 58.000 Oil type: naphthenic May 2005 The analysis and subsequent diagnosis performed by Sea Marconi on the equipment of the customer showed: Index of corrosiveness =1 (max level) ASTM b 48H= 4C Overall Health index: 0.52
Leia mais