Tag: PCB

26
Mai
2015

Japan orders its first system for the decontamination of PCBs to 0.5mg/kg

We are particularly proud to be able to recount another positive update in the “PCBs free Program for Japan” project: the arrival of the first order for the development of a system (DMU) for the dehalogenation of oils and transformers contaminated by PCBs. To completely understand the extraordinary nature of this news, we need to take a look at the
Leia mais
14
Fev
2015

IEC 62701, Sea Marconi also at the forefront of recycled oil solutions

In accordance with the IEC 62701 standard (Fluids for electrotechnical applications – Recycledmineral insulating oils for transformers and switchgear), Sea Marconi has developed an ad hoc project for one of the most important European suppliers of transformer oils. The project involves the implementation of a system for the assessment (technical-economical and environmental) of insulating oil properties before and after their reclamation (oil regeneration). In
Leia mais
30
Jan
2015

Sea Marconi technology exported to Mexico meets the expectations of the Comision Federal de Electricidad (CFE)

The partnership between Sea Marconi and local partner “Energy Solution SA DE CV“, a subsidiary of the NIETO group and an important player in the Mexican Oil & Gas sector, is enjoying great success. In 2014, the Sea Marconi process for the treatment of oils and transformers contaminated by PCBs, was successfully validated. The activity was performed in Torreón on
Leia mais

PCBs e corrosão C2 e C4, logística extrema – França 2013

Scenario Hydro Power Plant The transformer is located near a river dam with extreme logistical and environmental constraints. The option of changing the oil was discarded immediately because of the enormous difficulties in handling (see. Photo) around the transformer. At the same time the fuller earth techniques would not solve the functional criticalities of the system “oil – transformer”. Nameplate
Leia mais

Remoção de PCBs e proteção ambiental – França 2012

Scenario Nameplate data of transformer: Trasformatore: grid transformer Manufact: xxx Year: 1970 Power [MVA]: 70 Voltage [KV]: 225 Oil mass [Kg]: 38.000 Solution Sea Marconi Dealogenazione (CDP Process®) treatment in order to remove the PCBs, performed on-load (this means that the transformer is in service and under load during the treatment) Trend of PCBs and chlorine content during the dehalogenation treatment (CDP Process)
Leia mais

Remoção de PCBs e proteção ambiental – França 2008

Scenario Nameplate data of transformer: Transformer: GSU transformer Manufact: xxx Year: 1974 Power [MVA]: 760 Voltage [KV]: 400 Oil mass [Kg]: 55.000 Problem See analytical results of the oil before treatment (table below) Soluzione Sea Marconi Solution: Dehalogenation treatment (CDP Process®) in order to remove the PCBs from the oil and transformer. Before treatment After treatment TAN [mg KOH/g] 0,029 < 0,010 Breakdown
Leia mais

Removal of PCBs and environmental protection France 2004-2012

Scenario Utility – Power transformer of generation (nuclear, thermal, hydro), transmission and distribution with a total of 1.093 transformers. Namepale data of transformers: Power max [MVA]: 760 Voltage max [KV]: 400 Oil mass [Kg]: 75.000 each PCB max [mg/Kg]: 5.000 PCB target [mg/Kg]: < 20 (after 90 days) Solution Sea Marconi Solution: Dehalogenation treatment (CDP Process®) in order to remove the PCBs from oils and transformers. The treatments
Leia mais

Removal of PCBs and environmental protection Cyprus 1997

Scenario International Tender of the Electricity Authority of Cyprus for: “Elimination of PCBs from the insulating oil of distribution transformers”. In the 1997 Sea Marconi awarded the tender for decontaminate 520 transformers. Nameplate data of transformers: Power max [KVA]: 10-1000 Oil mass contaminated [Kg]: 94.000 PCB max [mg/Kg]: 15.000 PCB target [mg/Kg]: < 10 Solution Sea Marconi Solution: Dehalogenation treatment (CDP Process®) in order to remove
Leia mais

Removal of PCBs and non-DBDS corrosive sulfur (C2) France 2013

Scenario Nameplate data of transformer: Transformer: grid transformer Manufact: xxx Year: 1957 Power [MVA]: 50 Voltage [KV]: 225 Oil Mass [Kg]: 38.000 Oil type: blended mineral oil Trasformatore affetto da PCB e presenza di composti corrosivi solforati Solution Selective depolarization treatment (Chedcos) in order to remove corrosive sulfur compounds and dehalogenation treatment (CDP Process®) in order to remove the PCBs from oil and transformer. The treatment was
Leia mais

Removal of PCBs and non-DBDS corrosive sulfur (C2) France 2012

Scenario Hydro power plant with 3 GSU transformers Nameplate data of the transformer: Manufact: xxx Year: 1965 Power [MVA]: 80 Voltage [KV]: 220 Oil mass [Kg]: 35.000 Oil type: naphthenic blended Solution Selective deplarization treatment (Chedcos) in order to remove the corrosive sulfur compounds and dehalogenation treatments (CDP Process®) in order to remove the PCBs from the oil and the transformers. the tratments were performed
Leia mais