Tag: trattamento olio

27
Mai
2015

Two new oil decontamination plants enrich the Sea Marconi product range

The range of Sea Marconi systems has been enriched by an additional two elements, two mobile units for the physical treatment of oil. The new plants have been designed and developed to be lightweight (the estimated empty weight is 590 kg), with reduced bulk (L 1,560 x l 1,000 x h  1,440 (mm), and easy to move. This means they can also be transported on road trailers
Leia mais
26
Mai
2015

Sea Marconi will participate in the Monterrey seminar (Mexico) offering a solution to corrosive sulphur

The 6th “Seminario de Tecnología y Diagnóstico de Transformadores y Fluidos Aislantes” in Monterrey in Mexico has just come to an end, involving the participation of speakers from Sea Marconi. The event was organised by Weidmann and Prolec (General Electric) for all operators involved in the selection, purchase and management of electric transformers with insulating fluid. Over the three days, many themes were dealt
Leia mais
14
Fev
2015

IEC 62701, Sea Marconi also at the forefront of recycled oil solutions

In accordance with the IEC 62701 standard (Fluids for electrotechnical applications – Recycledmineral insulating oils for transformers and switchgear), Sea Marconi has developed an ad hoc project for one of the most important European suppliers of transformer oils. The project involves the implementation of a system for the assessment (technical-economical and environmental) of insulating oil properties before and after their reclamation (oil regeneration). In
Leia mais

Drying papers and transformer France 2008

Scenario Hydro power plant Nameplate data of transformer: Transformer: power transformer Year: 1948 Power [MVA]: 33 Voltage [KV]: 225 Oil mass [Kg]: 74.000  Solution Sea Marconi Solution: Dehydration treatment performed on-load (transformer fully load during the treatment) Before the treatment After the treatment After 6 months Oil temp. [°C] 15 63 35 Dissolved water [mg/Kg] IEC 60814 28 8 14 Saturation pecentage
Leia mais

Removal of corrosion from dissolved metals (C4) and sludge Italy 2003

Scenario Hydro power plant Nameplate data of transformer: Transformer: GSU transformer Power [MVA]: 30 Voltage [KV]: 130 Oil mass [Kg]: 58.000 Oil type: paraffinic Before the treatment Cu [mg/Kg] 43 TAN [mg KOH/g] 0,213 Color 3 DF 1,268 Solution Sea Marconi Solution: Selective Depolarization treatment (Chedcos) performed on-load (transformer fully load during the treatment) Selective depolarization treatment: Chedcos Before the treatment After the
Leia mais

Removal of corrosive sulfur from by-products of sulfur combustion (C3) Uruguay 2010

Scenario Uruguayan utility October 2012: Failure 2 weeks after a reclaim treatment with fuller earth (performed by a local operator). Nameplate data of the transformer: Transformer: grid transformer with OLTC Namufact.: xxx Year: 1977 Power [MVA]: 425 Voltage [KV]: 500 Oil mass [Kg]: 58.000 Oil type: YPF65 paraffinic oil not inhibited Segni di arco elettrico sui contatti del selettore Analysis and diagnosis (by the holder)
Leia mais

Removal of PCBs and non-DBDS corrosive sulfur (C2) France 2012

Scenario Hydro power plant with 3 GSU transformers Nameplate data of the transformer: Manufact: xxx Year: 1965 Power [MVA]: 80 Voltage [KV]: 220 Oil mass [Kg]: 35.000 Oil type: naphthenic blended Solution Selective deplarization treatment (Chedcos) in order to remove the corrosive sulfur compounds and dehalogenation treatments (CDP Process®) in order to remove the PCBs from the oil and the transformers. the tratments were performed
Leia mais

Removal of PCBs and non-DBDS corrosive sulfur (C2) France 2010

Scenario Steel Factory: 8 Equipment Nameplate data of the transformers: Namufact: xxx Year: 1973 Power [MVA]: 85 Voltage [KV]: 63 Oil mass [Kg]: 18.150 Oil type: naphthenic blended Fingerprint dell’olio. Si evidenzia la presenza di composti solforati responsabili della corrosività dell’olio Solution Selective depolarization treatment (Chedcos) in order to remove the corrosive sulfur compounds and dehalogenation treatments (CDP Process®) in order to remove the PCBs from the oils
Leia mais

Francia 2012 Rimozione zolfo corrosivo senza DBDS (C2)

Scenario Il classico trattamento con terre follari si dimostra totalmente inefficace contro lo zolfo corrosivo Caratteristiche tecniche del trasformatore: Costruttore: xxx Anno: 1969 Potenza [MVA]: 14 Tensione [KV]: 63 Massa olio [Kg]: 4.200 Tipo di olio: Esso Univol 54 Fingerprint dell’olio. Presenza di composti solforati NON DBDS Il trattamento con terre follari (NON da Sea Marconi) non ha prodotto alcun risultato
Leia mais

Remoção de enxofre corrosivo não-DBDS (C2) – Oriente Médio 2009

Scenario Thermal power plant with 8 GSU transformers Nameplate data of the transformers: Power [MVA]: 175 Voltage [KV]: 400 Oil type: naphthenic oil C2 – Corrosione NON legata a DBDS Step 1 The diagnosis in the 2009 showed: Total sulfur = 200 mg/Kg TCS (Total Corrosive Sulfur) = 157 mg/Kg (DBDS eq.) CCD Test = corrosive IFT = 19 mN/m DBTP
Leia mais