When DGA intercept the fault

GSU; 15/400 kV; 340 MVA; OFAF; sealed Installed on Summer 2005, filled with naphtenic oil, new oil controlled (no problem found). After 7 months: alert from Hydran sensor Monitoring: firstly each week, later daily. Gas Date 16/07/05 29/07/05 09/02/06 Loading reduction 15/02/06 Electrical tests 16/02/06 17/02/06 Oxygen ul/l 2651 5462 924 559 821 3055 Nitrogen ul/l 8934 18462 8122 3963
Read more
14
Feb
2008

Press release. New French headquarters for Sea Marconi

Homécourt, 12 February 2008 New French headquarters for Sea Marconi: technology and consideration for the environment Sea Marconi, a company based in Collegno (Italy), international leader in research, services and technologies for the protection of company assets a and the environment, continues its expansion with the inauguration of a new facility for offices and logistic/storage area. LSea Marconi France, after six years of activity
Read more
12
Jan
2008

Sea Marconi at the GCC Cigre Conference in Baharain

On 11th November 2008, Sea Marconi participated at the GCC Power 2008 in Baharain, the fourth GCC Cigre International Conference. Vander Tumiatti, founder partner of Sea Marconi, participated as speaker to the session titled Power Transformers and Substations.The presentation fully responded to the expectations generated by the topics in the title itself “Green Program D5 for the protection of fleets of Transformers
Read more
10
Jan
2008

A last good-bye for a dear friend: Viktor Sokolov

I was made aware, in the most complete astonishment, of the departure of Viktor Sokolov, and I wish to express my deepest sorrow. I learnt with the greatest suffering and affliction about his departure from a letter sent by his children (here below). Through the years when our roads have crossed each other’s, I realised how he represented a lighthouse for the
Read more
4
Sep
2007

CDP Process®, Best Available Technique according to the Italian Ministry of the

With pride we publish an abstract from OFFICIAL GAZETTE of the Republic of Italy of 7 June 2007 by Ministry of the Environment and the Protection of the Territory and the Seas.This legislative document implements in Italy European Directive 96/61/EC known as “IPPC” for the enacting of the guidelines for the identification of the Bets Available Techniques allowing the competent national and regional authorities
Read more
14
Jun
2007

Nanospunges won the prestigious award for Technology of the month in Germany

An Italian company, Sea Marconi, together with University of Turin have synthesized and patented a type of macromolecules, nanosponges, starting from natural oligosaccharides, cyclodextrins. These compounds can be exploited in several applications thanks to their unique and peculiar structure enabling the inclusion of several substances, that can be either strongly retained or released in a controlled way. So far, the
Read more
6
Mar
2007

List of tests performed by the Sea Marconi analyses laboratory

Description of tests and PACKAGES MO SO AK ES CC Method of measure 2-FAL and furanic compounds X X X X IEC 61198 Total Acidity (TAN) X X X IEC 62021 – 1/2 Water in papers and cardboards X IEC 60814 Water in Insulating Liquids X X X X IEC 60814 Phenolic anti oxidant additives (DBPC; DBP)  New X X IEC
Read more
5
Mar
2007

Dead or failed equipment are a mine of informations

It is very important to take samples of paper from the windings of transformers at the end of their life, to improve the models of furans interpretation and to have indications on the thermal aging of similar equipment. A brief list of controls on failed/dead transformers is: Visual inspection of windings degradation Paper DP, sampling from higher side of windings
Read more
5
Mar
2007

End of life degradation: the lost of thermal and mechanical properties of the insulation

The estimation of residual life of the transformer (even in approximation) is a dream. However is possible, by adequately monitoring some parameters, to estimate the state and rate of thermal degradation of papers. This can be made with different approaches. Equivalen DP estimation: Some authors defind relationships between 2-FAL concentration (or better total 2-FAL generated) and DP of the paper
Read more
28
Feb
2007

Diagnostic on fleet of similar transformers permits (often learning from previous failures) to prevent damages by operating specific actions

A group of 4 industrial transformers (25 MVA, 15/6 kV), in a petroleum refinery. Installed on 1993, one of them has an electric failure on 2004. The fault is later identified as due to corrosive sulfur (detachment of copper sulfide particles from naked copper, LV side, discharge to earth). Meanwhile the manufacturer repairs the equipment, and refill it with the
Read more